The Trane Z-Wave TZEMT400AB32MAA is a communicating thermostat for controlling heating and cooling HVAC systems, featuring Z-Wave RF communications for remote control. It includes a large backlit graphical LCD display, soft key navigation, scheduling up to 4 periods per day, energy usage graphs, filter/maintenance alerts, and compatibility with standard gas/electric and heat pump systems up to 2 stages compressor and 3 stages aux heat. Below are the key specifications and operation instructions.
1. Power On: Connect 24 VAC; display activates.
2. Set Time/Date: Menu > User Settings > Set Clock; adjust with +/-; press SET.
3. Set Mode/Fan: Press MODE (Off/Heat/Cool/Auto/Em Heat), FAN (Auto/On).
4. Z-Wave: Press learning button on back for inclusion/exclusion; follow controller instructions.
1. Display: Temp, setpoint, clock, mode/fan; LEDs for status (Sys Off/WAIT/Heat/Cool).
2. Controls: Soft keys for functions; Up/Down for setpoints; MENU for options.
3. Indicators: LEDs (green system/fan, red alerts); Backlight timeout adjustable.
1. Off: No operation.
2. Heat: Activates stages below setpoint; LED on.
3. Cool: Activates stages above setpoint; LED on.
4. Auto: Changeover between heat/cool.
5. Em Heat: Aux heat for heat pumps.
6. Fan: Auto or On.
1. Access: Press MENU > User Settings.
2. Options: Clock, sensor calibration (±7°F), backlight/contrast, filter/maintenance timers, F/C.
3. Schedules: Enable in installer; set 4 periods/day.
4. Alerts: Filter/Maint based on runtime; reset after service.
1. Scheduling: 7-day, 4 periods; copy days; heat/cool setpoints.
2. Z-Wave: Remote mode/setpoint/fan control; node ID in info screen.
3. Usage Graph: Weekly heat/cool runtime.
4. Staging: Auto based on deltas/MRT/MOT.
5. Display Lock: Installer option.
Warning: Qualified personnel only. Disconnect power. Follow lockout/tagout.
Terminal Designations (Heat Pump Example):
| Terminal | Description |
|---|---|
| 24COM | 24V Common |
| 24RC | 24V Hot (Cooling) |
| 24RH | 24V Hot (Heating) |
| W1 | Aux/Em Heat Stage 1 |
| W2 | Aux Heat Stage 2 |
| G | Fan |
| Y1 | Compressor Stage 1 |
| Y2 | Compressor Stage 2 |
| O/B | Reversing Valve |
Notes: Jumper RC/RH default; cut for dual transformers. Set system type in installer menu.
Estimate monthly energy savings from scheduling (assumes 3°F setback saving 0.12 kWh per hour unoccupied; 30 days/month).