The Trane XT500C is a deluxe programmable heat pump thermostat with features like worry-free programming, Comfort-R system for balanced temperature and humidity, Adaptive Intelligent Recovery for energy-efficient comfort, customizable 7-day schedules with four periods (Wake, Leave, Return, Sleep), and support for emergency/auxiliary heat. It includes a backlit LCD display, keyboard controls, filter indication, and outdoor temperature display (if equipped). Compatible with heat pump systems using O or B reversing valve. Below are the key specifications and operation instructions.
1. Power On: Display flashes 1:00 PM; press any key to activate.
2. Set Day/Time: Press Set Current Day/Time; select day (Mon-Sun) with Day key; adjust time with Time keys; enable DST if needed; press Run Program.
3. Set Mode/Fan: System: Heat/Cool/Off/Auto/Em Ht; Fan: Auto/On.
4. Program Schedule: Press Program; set periods/times/setpoints/fan; use preprogrammed defaults or customize.
1. Display: Day/time, period, room temp, setpoints, system/fan icons, filter status, low battery.
2. Controls: Increase/Decrease for temp; Information key (cycles outdoor temp, setpoints, filter); Program for schedule; Hold Temp for overrides; System/Fan keys.
3. Indicators: Flame/snowflake for heat/cool; "Hold"/"Temporary"; Filter flashing; "Em Ht"/"Aux" for emergency/aux heat.
1. Heat: Activates heat when below setpoint; flame icon.
2. Cool: Activates cool when above setpoint (after lockout); snowflake icon.
3. Auto: Switches heat/cool with deadband.
4. Off: No operation.
5. Em Heat: Uses auxiliary heat; bypasses compressor.
6. Fan: Auto (with calls) or On (continuous).
1. Access: Press Program for schedule; Filter for timer.
2. Scheduling: 7-day/24-hour/constant; edit periods (times 15-min increments, setpoints, fan); copy/clear days.
3. Filter Reset: Press Filter; hold 3s to reset/set days (0-360).
4. Overrides: Temporary Hold (until next period), indefinite, vacation (1-255 days).
5. Scale/Clock: Dealer-set (°F/°C, 12/24-hr); DST enable.
1. Adaptive Recovery: Starts early to reach setpoint on time; learns over 4-8 days.
2. Comfort-R: Balances temp/humidity.
3. Vacation Mode: Holds setpoints for specified days.
4. Outdoor Display: If equipped, via Information key.
5. Aux/Em Heat: Auto-activates if needed; manual Em Ht mode.
Warning: Qualified personnel only. Disconnect power. Follow lockout/tagout. Comply with codes.
Terminal Designations (Typical Heat Pump Hookup):
| Terminal | Description |
|---|---|
| R | 24V Hot (Power) |
| W | Aux/Em Heat |
| Y | Compressor |
| G | Fan |
| C | Common (required) |
| O/B | Reversing Valve |
Notes: Use TAYSENS100A relay for valve; provide overload protection/disconnect; see Fig. 3 for full diagram with contactors/transformer.
Estimate monthly energy savings from Adaptive Recovery scheduling (assumes 3°F setback saving 0.12 kWh per hour unoccupied; 30 days/month).