Trane XT500C Thermostat Operation Manual

The Trane XT500C is a deluxe programmable heat pump thermostat with features like worry-free programming, Comfort-R system for balanced temperature and humidity, Adaptive Intelligent Recovery for energy-efficient comfort, customizable 7-day schedules with four periods (Wake, Leave, Return, Sleep), and support for emergency/auxiliary heat. It includes a backlit LCD display, keyboard controls, filter indication, and outdoor temperature display (if equipped). Compatible with heat pump systems using O or B reversing valve. Below are the key specifications and operation instructions.

1. Key Specifications 2. Operation Instructions 2.1. Initial Setup 2.2. Home Screen Navigation 2.3. Operating Modes 2.4. Settings Screen 2.5. Advanced Features 2.6. Troubleshooting 3. Installation Instructions 3.1. Pre-Installation 3.2. Wiring Diagrams 3.3. Configuration Options 4. Calculation Tool

Key Specifications

Operation Instructions

Initial Setup

1. Power On: Display flashes 1:00 PM; press any key to activate.
2. Set Day/Time: Press Set Current Day/Time; select day (Mon-Sun) with Day key; adjust time with Time keys; enable DST if needed; press Run Program.
3. Set Mode/Fan: System: Heat/Cool/Off/Auto/Em Ht; Fan: Auto/On.
4. Program Schedule: Press Program; set periods/times/setpoints/fan; use preprogrammed defaults or customize.

Home Screen Navigation

1. Display: Day/time, period, room temp, setpoints, system/fan icons, filter status, low battery.
2. Controls: Increase/Decrease for temp; Information key (cycles outdoor temp, setpoints, filter); Program for schedule; Hold Temp for overrides; System/Fan keys.
3. Indicators: Flame/snowflake for heat/cool; "Hold"/"Temporary"; Filter flashing; "Em Ht"/"Aux" for emergency/aux heat.

Operating Modes

1. Heat: Activates heat when below setpoint; flame icon.
2. Cool: Activates cool when above setpoint (after lockout); snowflake icon.
3. Auto: Switches heat/cool with deadband.
4. Off: No operation.
5. Em Heat: Uses auxiliary heat; bypasses compressor.
6. Fan: Auto (with calls) or On (continuous).

Settings Screen

1. Access: Press Program for schedule; Filter for timer.
2. Scheduling: 7-day/24-hour/constant; edit periods (times 15-min increments, setpoints, fan); copy/clear days.
3. Filter Reset: Press Filter; hold 3s to reset/set days (0-360).
4. Overrides: Temporary Hold (until next period), indefinite, vacation (1-255 days).
5. Scale/Clock: Dealer-set (°F/°C, 12/24-hr); DST enable.

Advanced Features

1. Adaptive Recovery: Starts early to reach setpoint on time; learns over 4-8 days.
2. Comfort-R: Balances temp/humidity.
3. Vacation Mode: Holds setpoints for specified days.
4. Outdoor Display: If equipped, via Information key.
5. Aux/Em Heat: Auto-activates if needed; manual Em Ht mode.

Troubleshooting

Installation Instructions

Warning: Qualified personnel only. Disconnect power. Follow lockout/tagout. Comply with codes.

Pre-Installation

Wiring Diagrams

Terminal Designations (Typical Heat Pump Hookup):

TerminalDescription
R24V Hot (Power)
WAux/Em Heat
YCompressor
GFan
CCommon (required)
O/BReversing Valve

Notes: Use TAYSENS100A relay for valve; provide overload protection/disconnect; see Fig. 3 for full diagram with contactors/transformer.

Configuration Options

  1. Mount wallplate horizontally; connect wires per diagram.
  2. Power up; enter Installer Setup (hold Increase): Set system type (heat pump), changeover (auto), fan (gas/electric), cycle rates, min off time (5 min), compressor protection, DST, accessory output.
  3. Review settings; exit with Run Program.
  4. Perform self-test: Heat/Cool/Em Heat/Fan/Aux/Filter/Comfort-R.
  5. Set user day/time/program.

Calculation Tool

Estimate monthly energy savings from Adaptive Recovery scheduling (assumes 3°F setback saving 0.12 kWh per hour unoccupied; 30 days/month).