The Trane XT302C is a deluxe programmable heat-cool thermostat for 24 VAC single-stage heating and cooling systems. It features automatic changeover, 7-day programming with 4 periods (Wake, Leave, Return, Sleep), keyboard controls for time, temperature, day, and programs, on-auto fan selection, temporary overrides, recovery mode, and installer setup options including compressor protection. Below are the key specifications and operation instructions.
1. Power On: Display activates; if flashing, press any key.
2. Set Day/Time: Press Set Current Day/Time; adjust day with Day key; time with Time keys; enable DST if needed.
3. Set Mode/Fan: Press System for Heat/Off/Cool/Auto; Fan for On/Auto.
4. Program Schedule: Press Program; set periods/times/setpoints; copy days if 7-day mode.
1. Display: Day/time, period, room temp, mode icons, filter status, low battery.
2. Controls: Increase/Decrease for temp; System/Fan keys; Hold Temp for overrides; Program for schedule.
3. Indicators: Flame/snowflake for active; Temporary for overrides; Filter flashing.
1. Heat: Controls heating when below setpoint.
2. Cool: Controls cooling when above setpoint (after delay).
3. Auto: Automatic changeover with deadband.
4. Off: No operation.
5. Fan: On (continuous) or Auto (with calls); programmable per period.
1. Access: Use Program key for schedule; Filter for timer.
2. Schedule: 7-day (unique days), 24-hour (daily repeat), or constant setpoint; 4 periods.
3. Filter Timer: Set 0-360 days; reset when changed.
4. Overrides: Temporary (until next period), indefinite hold, or vacation (1-255 days).
1. Programming: Preprogrammed defaults; customize times/setpoints/fan; copy/clear periods.
2. Adaptive Recovery: Learns to start early for exact setpoint at period start.
3. Information Key: Cycles outdoor temp, setpoints, filter status.
4. Daylight Savings: Auto-adjust clock.
5. Comfort-R: Balances temp/humidity.
Warning: Qualified personnel only. Disconnect power. Follow lockout/tagout. Comply with codes.
Terminal Designations (Single-Stage Heat/Cool):
| Terminal | Description |
|---|---|
| R | 24V Hot (Power) |
| W | Heat Relay |
| Y | Cool Compressor |
| G | Fan |
| C | Common (required) |
Notes: Multistage support; use heat relay if needed; overload protection required. See diagrams for electric heat (set fan to electric).
Estimate monthly energy savings from programming (assumes 4°F setback saving 0.15 kWh per hour unoccupied; 30 days/month).