The Trane XT300C is a deluxe programmable heat-cool thermostat for 24 VAC single-stage heating and cooling systems. It features automatic changeover, 7-day programming with 4 periods (Wake, Leave, Return, Sleep), keyboard controls for time, temperature, day, and programs, on-auto fan selection, temporary overrides, recovery mode, and installer setup options including compressor protection. It does not support emergency heat or outdoor temperature display. Below are the key specifications and operation instructions.
1. Power On: After installation, batteries activate display.
2. Set Time/Date: Press Time key; adjust hour/minutes/day with Temp arrows; press Time to confirm.
3. Set Mode/Fan: System: Heat/Off/Cool/Auto; Fan: On/Auto.
4. Program Schedule: Press Program; set periods (Wake/Leave/Return/Sleep) with times/setpoints; copy to days.
1. Display: Room temp, setpoints, time, day, program period, system/fan status, low battery (Repl Batt).
2. Controls: Temp arrows for setpoints; System/Fan keys; Hold for override; Program for schedule; Time for clock.
3. Indicators: Heat/Cool On; Hold active; program period names.
1. Heat: Activates heat when below setpoint.
2. Cool: Activates cool when above setpoint (after 5-min delay).
3. Auto: Automatic changeover with 3°F deadband.
4. Off: No operation.
5. Fan: On (continuous) or Auto (with calls).
1. Access: Use Time/Program keys for clock/schedule; installer setup via Temp keys + Time.
2. Options: Clock format (12/24 hr), scale (°F/°C), auto changeover (on/off), fan control, compressor min off (5 min), changeover differential, setpoint limits.
3. Scheduling: 4 periods/day; set times/heat/cool setpoints; 7-day or copy days.
4. Overrides: Temporary Hold (returns to program); permanent via setpoint adjustment.
1. Programming: 7-day schedule; recovery for gradual adjustment to next period.
2. Self-Test: Press Temp keys then Time; tests heat/cool/fan/keyboard.
3. Device Info: In self-test (70); view software/model.
4. Compressor Protection: 5-min minimum off timer.
Warning: Qualified personnel only. Disconnect power. Follow lockout/tagout. Comply with codes.
Terminal Designations (Single-Stage Heat/Cool with One Transformer):
| Terminal | Description |
|---|---|
| R | 24V Hot (Power) |
| W | Heat Relay |
| Y | Cool Compressor |
| G | Fan |
| C | Common (required for cooling-only) |
Notes: Use heat relay (TAYSTAT253A) if system requires; provide overload protection; for cooling-only, wire per specific diagram.
Estimate monthly energy savings from programming (assumes 4°F setback saving 0.15 kWh per hour unoccupied; 30 days/month).