The Trane XR401 Comfort Control (TCONT401AN21MA) is a digital non-programmable thermostat for 2-heat/1-cool conventional and heat pump systems. It features a backlit LCD display, separate heating/cooling setpoints, auto changeover, energy savings mode, filter reminder, outdoor temperature display (with sensor), and non-volatile memory for settings retention. Below are the key specifications and operation instructions.
1. Power On: Ensure furnace power is ON and blower door secure; display activates automatically.
2. User Setup: Press and hold MODE + FAN; use MODE to advance, FAN to back, arrows to adjust.
3. Set Mode/Fan: Press MODE for Heat/Cool/Off/Auto/Em Heat; FAN for Auto/On.
4. Adjust Setpoints: Use up/down arrows; defaults 68°F heat/78°F cool.
1. Display: Indoor temp, setpoint, mode (bordered), outdoor temp, fan status, alerts (filter/OD).
2. Controls: Up/down arrows for setpoint; MODE/FAN buttons; FILTER/OD for reminders/outdoor view.
3. Indicators: Border around active mode; flashing FILTER/OD for alerts.
1. Heat: Activates heat when below setpoint.
2. Cool: Activates cool when above setpoint (5-min delay).
3. Auto: Switches heat/cool with deadband.
4. Off: No operation.
5. Emergency Heat: For heat pumps; aux heat only.
6. Energy Savings: Adjusts setpoint for efficiency (warmer cool, cooler heat).
7. Fan: Auto (with calls) or On (continuous).
1. Access: Hold MODE + FAN for User Setup.
2. Options: Outdoor calibration (±5°F), filter timer (days), deadband (for Auto).
3. Filter Reset: Press FILTER/OD when flashing.
4. Setpoints: Separate heat/cool; 1°F increments.
1. Auto Changeover: Enable in setup; deadband prevents short cycling.
2. Energy Savings: Press button; auto-adjusts for lower energy use.
3. Filter Reminder: Set timer; flashes when due.
4. Outdoor Display: With sensor; calibrate in setup.
5. Non-Volatile Memory: Retains settings without batteries.
Warning: Qualified personnel only. Disconnect power. Follow lockout/tagout. Comply with codes.
Terminal Designations (Typical for 2H/1C):
| Terminal | Description |
|---|---|
| R | 24V Hot |
| C | Common |
| W1 | Heat Stage 1 |
| W2 | Heat Stage 2/Aux |
| Y1 | Compressor Stage 1 |
| G | Fan |
| O/B | Reversing Valve |
| OS1/OS2 | Outdoor Sensor |
Notes: External relay for oil; TAYPLUS103A for dual fuel. See diagrams for specific configs (e.g., single stage cool/heat).
Estimate monthly energy savings from Energy Savings mode (assumes 2°F adjustment saving 0.1 kWh per hour; 30 days/month).