Trane XR401 Comfort Control Operation Manual

The Trane XR401 Comfort Control (TCONT401AN21MA) is a digital non-programmable thermostat for 2-heat/1-cool conventional and heat pump systems. It features a backlit LCD display, separate heating/cooling setpoints, auto changeover, energy savings mode, filter reminder, outdoor temperature display (with sensor), and non-volatile memory for settings retention. Below are the key specifications and operation instructions.

1. Key Specifications 2. Operation Instructions 2.1. Initial Setup 2.2. Home Screen Navigation 2.3. Operating Modes 2.4. Settings Screen 2.5. Advanced Features 2.6. Troubleshooting 3. Installation Instructions 3.1. Pre-Installation 3.2. Wiring Diagrams 3.3. Configuration Options 4. Calculation Tool

Key Specifications

Operation Instructions

Initial Setup

1. Power On: Ensure furnace power is ON and blower door secure; display activates automatically.
2. User Setup: Press and hold MODE + FAN; use MODE to advance, FAN to back, arrows to adjust.
3. Set Mode/Fan: Press MODE for Heat/Cool/Off/Auto/Em Heat; FAN for Auto/On.
4. Adjust Setpoints: Use up/down arrows; defaults 68°F heat/78°F cool.

Home Screen Navigation

1. Display: Indoor temp, setpoint, mode (bordered), outdoor temp, fan status, alerts (filter/OD).
2. Controls: Up/down arrows for setpoint; MODE/FAN buttons; FILTER/OD for reminders/outdoor view.
3. Indicators: Border around active mode; flashing FILTER/OD for alerts.

Operating Modes

1. Heat: Activates heat when below setpoint.
2. Cool: Activates cool when above setpoint (5-min delay).
3. Auto: Switches heat/cool with deadband.
4. Off: No operation.
5. Emergency Heat: For heat pumps; aux heat only.
6. Energy Savings: Adjusts setpoint for efficiency (warmer cool, cooler heat).
7. Fan: Auto (with calls) or On (continuous).

Settings Screen

1. Access: Hold MODE + FAN for User Setup.
2. Options: Outdoor calibration (±5°F), filter timer (days), deadband (for Auto).
3. Filter Reset: Press FILTER/OD when flashing.
4. Setpoints: Separate heat/cool; 1°F increments.

Advanced Features

1. Auto Changeover: Enable in setup; deadband prevents short cycling.
2. Energy Savings: Press button; auto-adjusts for lower energy use.
3. Filter Reminder: Set timer; flashes when due.
4. Outdoor Display: With sensor; calibrate in setup.
5. Non-Volatile Memory: Retains settings without batteries.

Troubleshooting

Installation Instructions

Warning: Qualified personnel only. Disconnect power. Follow lockout/tagout. Comply with codes.

Pre-Installation

Wiring Diagrams

Terminal Designations (Typical for 2H/1C):

TerminalDescription
R24V Hot
CCommon
W1Heat Stage 1
W2Heat Stage 2/Aux
Y1Compressor Stage 1
GFan
O/BReversing Valve
OS1/OS2Outdoor Sensor

Notes: External relay for oil; TAYPLUS103A for dual fuel. See diagrams for specific configs (e.g., single stage cool/heat).

Configuration Options

  1. Mount base; connect wires per diagram.
  2. Power up; access Installer Setup (MODE + UP hold): Set system type, cycle rates, etc.
  3. Configure: Heat pump/AC, gas/electric, outdoor sensor, filter timer.
  4. Test: Normal/manual modes for fan/heat/cool.
  5. User setup for calibration/deadband.

Calculation Tool

Estimate monthly energy savings from Energy Savings mode (assumes 2°F adjustment saving 0.1 kWh per hour; 30 days/month).