The Trane XR203 (TCONT203) is a programmable push-button thermostat with a 3.5-inch backlit display for heat/cool and heat pump systems up to 4 stages of heat and 2 stages of cool. It supports 7-day, 5-1-1, or non-programmable scheduling with up to 4 periods per day, temporary overrides, permanent hold, early start, circulation fan, auto changeover, filter reminders, keypad lock, and compressor lockout. Below are the key specifications and operation instructions.
1. Install Batteries: Remove battery tag; insert 2 AA alkaline batteries.
2. Set Time/Date: Press Menu; adjust time/day with arrows; press Exit.
3. Set Mode/Fan: System: Heat/Cool/Off/Auto/Em Heat; Fan: Auto/On.
4. Schedule Type: Menu > Settings > Select 7-day/5-1-1/non-programmable.
1. Display: Current temp, setpoint, time/day, mode icons, battery status, alerts (e.g., filter, service).
2. Controls: Arrows for setpoint; Hold/Run for override; Menu for settings/schedule; Fan/System buttons.
3. Indicators: Heat On/Cool On/Aux On; Hold; Lock; FAn (circulation); Starting Soon (lockout).
1. Auto: Automatic heat/cool changeover (enable in settings).
2. Heat: Activates heat stages when below setpoint; Aux if needed.
3. Cool: Activates cool stages when above setpoint.
4. Off: No operation.
5. Emergency Heat: For heat pumps; uses aux heat only.
6. Fan: Auto (with calls), On (continuous), Program (circulation %).
1. Access: Press Menu > Settings.
2. Options: Schedule type (7/5-1-1/0), periods (2/4), early start, circulation fan (10-100%), scale (°F/°C), temp adjustment (±5°F), display light, filter reminder (1-12 mo), auto changeover.
3. Scheduling: Menu > Schedule; edit times/setpoints for periods (P1-P4) per day/group.
4. Overrides: Temporary (2+ hrs) or permanent Hold.
1. Scheduling: 4 periods/day; factory defaults: Wake 6AM 70/78, Leave 8AM 62/85, Return 5PM 70/78, Sleep 10PM 62/82.
2. Early Start: Pre-conditions to reach setpoint on time.
3. Circulation Fan: Min run time % (e.g., 30% daily).
4. Keypad Lock: Hold up + Menu; unlock same.
5. Compressor Lockout: 5-min delay (Installer menu).
6. Cycle Rates: Fast/Med/Slow for heat/aux/cool.
Warning: Qualified personnel only. Disconnect power. Follow lockout/tagout. Comply with codes.
Terminal Designations (Common):
| Terminal | Description |
|---|---|
| Rc | 24V Hot (Cooling) |
| Rh | 24V Hot (Heating) |
| O/B | Reversing Valve |
| Y/Y1 | Compressor Stage 1 |
| Y2 | Compressor Stage 2 |
| G | Fan |
| W/E | Heat Stage 1/Emergency |
| W2 | Heat Stage 2/Aux |
| C | Common |
| L | System Monitor |
Notes: Jumper Rc/Rh if single transformer (clip if separate). Specific diagrams for TAM7/TAM9, S9V2, SV92, GAF2-S, etc. Wire condensate switches between Y and Y1. X2 for aux during defrost.
Estimate monthly energy savings from scheduling (assumes 3°F setback saving 0.15 kWh per hour unoccupied; 30 days/month).