Trane XR203 Thermostat Operation Manual

The Trane XR203 (TCONT203) is a programmable push-button thermostat with a 3.5-inch backlit display for heat/cool and heat pump systems up to 4 stages of heat and 2 stages of cool. It supports 7-day, 5-1-1, or non-programmable scheduling with up to 4 periods per day, temporary overrides, permanent hold, early start, circulation fan, auto changeover, filter reminders, keypad lock, and compressor lockout. Below are the key specifications and operation instructions.

1. Key Specifications 2. Operation Instructions 2.1. Initial Setup 2.2. Home Screen Navigation 2.3. Operating Modes 2.4. Settings Screen 2.5. Advanced Features 2.6. Troubleshooting 3. Installation Instructions 3.1. Pre-Installation 3.2. Wiring Diagrams 3.3. Configuration Options 4. Calculation Tool

Key Specifications

Operation Instructions

Initial Setup

1. Install Batteries: Remove battery tag; insert 2 AA alkaline batteries.
2. Set Time/Date: Press Menu; adjust time/day with arrows; press Exit.
3. Set Mode/Fan: System: Heat/Cool/Off/Auto/Em Heat; Fan: Auto/On.
4. Schedule Type: Menu > Settings > Select 7-day/5-1-1/non-programmable.

Home Screen Navigation

1. Display: Current temp, setpoint, time/day, mode icons, battery status, alerts (e.g., filter, service).
2. Controls: Arrows for setpoint; Hold/Run for override; Menu for settings/schedule; Fan/System buttons.
3. Indicators: Heat On/Cool On/Aux On; Hold; Lock; FAn (circulation); Starting Soon (lockout).

Operating Modes

1. Auto: Automatic heat/cool changeover (enable in settings).
2. Heat: Activates heat stages when below setpoint; Aux if needed.
3. Cool: Activates cool stages when above setpoint.
4. Off: No operation.
5. Emergency Heat: For heat pumps; uses aux heat only.
6. Fan: Auto (with calls), On (continuous), Program (circulation %).

Settings Screen

1. Access: Press Menu > Settings.
2. Options: Schedule type (7/5-1-1/0), periods (2/4), early start, circulation fan (10-100%), scale (°F/°C), temp adjustment (±5°F), display light, filter reminder (1-12 mo), auto changeover.
3. Scheduling: Menu > Schedule; edit times/setpoints for periods (P1-P4) per day/group.
4. Overrides: Temporary (2+ hrs) or permanent Hold.

Advanced Features

1. Scheduling: 4 periods/day; factory defaults: Wake 6AM 70/78, Leave 8AM 62/85, Return 5PM 70/78, Sleep 10PM 62/82.
2. Early Start: Pre-conditions to reach setpoint on time.
3. Circulation Fan: Min run time % (e.g., 30% daily).
4. Keypad Lock: Hold up + Menu; unlock same.
5. Compressor Lockout: 5-min delay (Installer menu).
6. Cycle Rates: Fast/Med/Slow for heat/aux/cool.

Troubleshooting

Installation Instructions

Warning: Qualified personnel only. Disconnect power. Follow lockout/tagout. Comply with codes.

Pre-Installation

Wiring Diagrams

Terminal Designations (Common):

TerminalDescription
Rc24V Hot (Cooling)
Rh24V Hot (Heating)
O/BReversing Valve
Y/Y1Compressor Stage 1
Y2Compressor Stage 2
GFan
W/EHeat Stage 1/Emergency
W2Heat Stage 2/Aux
CCommon
LSystem Monitor

Notes: Jumper Rc/Rh if single transformer (clip if separate). Specific diagrams for TAM7/TAM9, S9V2, SV92, GAF2-S, etc. Wire condensate switches between Y and Y1. X2 for aux during defrost.

Configuration Options

  1. Mount sub-base; connect wires per diagram.
  2. Power up; access Installer Menu (hold Menu 8s): Set outdoor (AC1/2/HP1/2), indoor (GA/EL/FAN), emergency (On/Off), O/B (O/B/3), fan %, cycle rates, lockout, limits, schedule type, early start, scale, adjustment, light, filter, auto changeover, lock.
  3. Test: Fan On/Auto, Heat/Cool calls, Aux.
  4. Set user schedule/time.
  5. Reset if needed (remove batteries 2 min).

Calculation Tool

Estimate monthly energy savings from scheduling (assumes 3°F setback saving 0.15 kWh per hour unoccupied; 30 days/month).