Trane XR202 Thermostat Operation Manual

The Trane XR202 (TCONT202) is a programmable push-button single-stage thermostat with a 3.5-inch backlit display for heat/cool systems up to 1H/1C. It supports 7-day, 5-1-1 scheduling, temporary overrides, early start, filter reminders, and keypad lock. Below are the key specifications and operation instructions.

1. Key Specifications 2. Operation Instructions 2.1. Initial Setup 2.2. Home Screen Navigation 2.3. Operating Modes 2.4. Settings Screen 2.5. Advanced Features 2.6. Troubleshooting 3. Installation Instructions 3.1. Pre-Installation 3.2. Wiring Diagrams 3.3. Configuration Options 4. Calculation Tool

Key Specifications

Operation Instructions

Initial Setup

1. Install Batteries: Insert 2 AA alkaline batteries; remove tag.
2. Set Time/Date: Press Set Time; adjust hour/minutes/day with arrows; press Exit.
3. Set Mode/Fan: System switch: Heat/Cool/Off; Fan: Auto/On.
4. Schedule Type: User Menu > 01: Select 7-day, 5-1-1, or non-programmable.

Home Screen Navigation

1. Display: Time, room temp, setpoint, day, battery, status icons.
2. Controls: Arrows for setpoint/override; Hold for permanent; Menu for options; Backlight button.
3. Indicators: Heat On/Cool On; Hold; Lock; Low battery; Filter reminder.

Operating Modes

1. Heat: System to Heat; setpoint above room; activates after delay.
2. Cool: System to Cool; setpoint below room; compressor after 5-min lockout.
3. Off: No operation.
4. Auto: Changeover supported.
5. Fan: Auto (with calls) or On (continuous).

Settings Screen

1. Access: Press Menu > Settings.
2. Options: Schedule type, early start, °F/°C, temp adjustment (±5°F), display light, filter reminder (1-12 months).
3. Schedule Edit: In Heat/Cool, Menu > Next; adjust periods P1-P4 for days.
4. Installer Menu: Hold Menu 8s for cycle rates, lockout, limits.

Advanced Features

1. Scheduling: 4 periods/day; 7-day or 5-1-1; factory defaults provided.
2. Overrides: Temporary (2+ hrs), permanent Hold.
3. Early Start: Pre-heats/cools to reach setpoint on time.
4. Keypad Lock: Hold up arrow + Menu.
5. Compressor Protection: 5-min off timer.

Troubleshooting

Installation Instructions

Warning: Qualified personnel only. Disconnect power. Follow lockout/tagout.

Pre-Installation

Wiring Diagrams

Terminal Designations:

TerminalDescription
RC24V Hot (Cooling)
RH24V Hot (Heating)
WHeat Stage 1
YCompressor Stage 1
GFan
O/BReversing Valve
CCommon

Notes: Factory jumper RC/RH (clip if separate); Gas/Electric switch; O/B to O (default) or B. Jumper Y-W for heat pump. Specific diagrams for various Trane systems.

Configuration Options

  1. Mount sub-base; connect wires per diagram.
  2. Power up; set time/day.
  3. Installer Menu: Cycle rates, lockout, limits, etc.
  4. Test fan/heat/cool.
  5. Set user schedule.

Calculation Tool

Estimate monthly energy savings from scheduling (assumes 3°F setback saving 0.15 kWh per hour unoccupied; 30 days/month).