The Trane XR103 (TCONT103) is a non-programmable digital thermostat designed for heat pump systems up to 2 stages of heat and 1 stage of cool. It features a simple interface with up/down arrows for setpoint adjustment, SYSTEM and FAN switches, battery-powered operation (with optional 24V common), auto changeover, emergency heat mode, and a 5-minute compressor protection delay. Below are the key specifications and operation instructions.
1. Install Batteries: Insert 2 AA alkaline batteries into the compartment.
2. Mount Thermostat: Follow installation; power from system if C wired.
3. Set Initial Mode: Use SYSTEM switch to select HEAT, COOL, or OFF.
4. Adjust Setpoint: Use up/down arrows to set desired temperature.
1. Display: Shows current room temperature, setpoint, mode icons (flame for heat, snowflake for cool), low battery symbol, malfunction indicator.
2. Controls: Up/down arrows for setpoint; SYSTEM switch (HEAT/OFF/COOL); FAN switch (AUTO/ON).
3. Indicators: Flame icon in HEAT; to prevent static, touch battery compartment before keys.
1. Off: No heating or cooling; fan off unless ON.
2. Heat: Activates heat when below setpoint; flame icon.
3. Cool: Move SYSTEM to COOL; press down arrow below room temp; blower on high, then cold air.
4. Auto: Automatic changeover (not explicitly detailed, but supported).
5. Em Heat: For heat pumps; uses auxiliary heat.
6. Fan: AUTO (with calls) or ON (continuous).
No programmable settings; adjustments via switches and arrows. 1°F increments. Compressor protection: 5-minute minimum off time.
1. Auto Changeover: Switches between heat and cool.
2. Compressor Protection: 5-minute delay.
3. Battery Backup: Operates without C wire.
Warning: Qualified personnel only. Disconnect power. Follow lockout/tagout. Comply with codes.
Terminal Designations (Standard for Heat Pump Configurations):
| Terminal | Description |
|---|---|
| R | 24V Hot |
| C | Common (optional) |
| Y/Y1 | Compressor Stage 1 |
| W1 | Aux Heat Stage 1 |
| G | Fan |
| O/B | Reversing Valve |
| X2 | Aux Heat during Defrost (some setups) |
Notes: Wire third-party condensate switches between Y and Y1. X2 for aux during defrost in variable speed furnaces. Specific diagrams for TAM, gas furnace, packages, etc. Jumper if single transformer.
Estimate monthly energy savings from manual adjustments (assumes 2°F setback saving 0.1 kWh per hour; 30 days/month).