The Trane XR102 (TCONT102) is a non-programmable digital thermostat for single-stage conventional and heat pump systems. It features a simple interface with up/down arrows for setpoint adjustment, system and fan switches, battery-powered operation (with optional 24V common), auto changeover, emergency heat mode, and a 4-minute compressor protection delay. Below are the key specifications and operation instructions.
1. Install Batteries: Insert 2 AA alkaline batteries; low battery icon appears when replacement needed.
2. Mount Thermostat: Follow installation steps; power from system if C wired.
3. Set System Type: No configuration needed; defaults to heat/cool.
4. Adjust Setpoints: Use up/down arrows for initial heat/cool temperatures.
1. Display: Shows current room temperature, setpoint, mode icons (heat/cool), low battery symbol.
2. Controls: Up/down arrows to adjust setpoint; SYSTEM switch for mode selection; FAN switch for fan control; HOLD button for temporary override.
3. Indicators: Flame for heat, snowflake for cool; compressor delay countdown if applicable.
1. Off: No heating or cooling; fan off unless set to On.
2. Heat: Activates heat when below setpoint; flame icon.
3. Cool: Activates cooling when above setpoint; snowflake icon.
4. Auto: Switches between heat and cool based on setpoints (3°F deadband default).
5. Em Heat: Emergency heat for heat pumps; uses auxiliary heat.
6. Fan: Auto (runs with system calls) or On (continuous).
No advanced settings menu; adjustments via physical switches and buttons. Setpoints stored simultaneously for heat and cool. Increments of 1°F. Compressor protection: 4-minute minimum off time.
1. Auto Changeover: Automatically switches between heat and cool modes.
2. Compressor Protection: 4-minute delay to prevent short cycling.
3. HOLD Function: Press HOLD to override automatic operation temporarily.
4. Battery Operation: Functions without C wire using batteries.
Warning: Qualified personnel only. Disconnect power. Follow lockout/tagout.
Terminal Designations (Common for most configurations):
| Terminal | Description |
|---|---|
| R | 24V Hot |
| C | Common (optional for battery mode) |
| W | Heat Stage 1 |
| Y/Y1 | Compressor Stage 1 |
| G | Fan |
| O/B | Reversing Valve (for heat pumps) |
Notes: Specific diagrams for cooling with TAM7/TAM9, S9V2 furnace, heat/cool packages, etc. Connect third-party switches between Y and Y1 for condensate. X2 for aux heat during defrost in some setups. Jumper if single transformer.
Estimate monthly energy savings from manual setpoint adjustments (assumes 2°F adjustment saving 0.1 kWh per hour; 30 days/month).