The Trane XL950 (ComfortLink II XL950 Control, TZONE950AC52ZA) is an advanced touch-screen communicating thermostat designed for Trane HVAC systems, including zoned environments. It features wireless connectivity for remote management via Nexia™ Home Intelligence, weather integration, programmable scheduling with guided setup, humidity control, air cleaner cycles, customizable home screen, and support for multi-system homes. Compatible with communicating and 24V systems via optional relay panel. Below are the key specifications and operation instructions.
1. Power On: Apply 24 VAC; auto-discovery for communicating systems.
2. Set Time/Date: Menu > Settings > Time & Date; auto-sync via wireless.
3. System Naming: Assign name for multi-system homes.
4. Scheduling: Use Guided Scheduling wizard or manual setup.
5. Wireless Setup: Enable radio, connect to 802.11 b/g network, register for Nexia™.
1. Display: Customizable dashboard with status, zones, weather, alerts.
2. Controls: Touch Menu for options; arrows for zones/photos; Help button for guidance.
3. Indicators: System mode icons, fan status, humidity levels, screen saver with temp overlay.
1. Auto: Automatic heat/cool changeover.
2. Heat: Activates heating stages.
3. Cool: Activates cooling stages.
4. Off: No operation.
5. Emergency Heat: For heat pumps.
6. Fan: Auto, On, Circulate (10-55 min/hr).
7. Air Cleaner: Auto, Quick Clean (3 hrs), Allergy Clean (24 hrs).
1. Access: Home > Menu > Settings.
2. Scheduling: Edit periods, copy days/zones; enable/disable.
3. Humidity: Adjust setpoints for heat/cool.
4. Screen Saver: Load photos via SD, set timeout (5-60 sec).
5. Security: Set PIN (default 1234).
6. Reminders: Filter, service alerts.
1. Nexia™ Integration: Remote control, weather forecasts, email alerts.
2. Zoning: Per-zone schedules, status; copy between zones.
3. Software Updates: Auto via internet or SD card.
4. Events/Vacations: Temporary schedule overrides.
5. Diagnostics: Network checks, system status.
6. Customization: Shortcuts, multi-system wireless linking.
Warning: Qualified personnel only. Disconnect power. Follow lockout/tagout.
Terminal Designations (Communicating System):
| Terminal | Description |
|---|---|
| R | 24V Hot |
| B | 24V Common |
| D | Data (ComfortLink II) |
| RS | Remote Sensor |
| ODT | Outdoor Temp Sensor |
For 24V Systems: Use BAY24VRPAC52DA Relay Panel; additional terminals Y1/Y2 (comp stages), W1/W2/W3 (heat), G (fan), O/B (rev valve). 3-wire to thermostat (B, D, R). Jumper if single transformer.
Estimate monthly energy savings from scheduling (assumes 3°F setback saving 0.12 kWh per hour unoccupied; 30 days/month).