The Trane TZONE950AC52ZA (ComfortLink II XL950) is a 7-inch color touch screen communicating thermostat for HVAC and zoning systems. It supports heat pump, heat/cool, dual fuel configurations, load-based staging, dehumidification/humidification/ventilation control, and integration with Trane communicating equipment. Features include 1-Touch Presets, Aggressive Recovery, diagnostics, and wireless multi-system linking. Below are the key specifications and operation instructions.
1. Power Up: Connect power (R/B/D); auto-discovery for communicating systems.
2. Manual Setup: For 24V: Installer Setup via Technician Access (hold 5 sec).
3. Wireless: Configure via User’s Guide for weather/multi-system.
4. Calibrate: Sensors (±5°F indoor temp/RH, ±10°F outdoor).
1. Display: Setpoints, modes, alerts; touch for details.
2. Controls: Touch screen; Menu for settings; Help button for info.
3. Indicators: Alerts, load values, zoning status.
1. Heat: Select Heat; load-based staging; humidification.
2. Cool: Select Cool; dehumidification.
3. Off: No operation.
4. Auto: Changeover with deadband.
5. Emergency Heat: Aux heat bypass.
6. Fan: On (35-100% variable), Auto, Circulate (10-55 min/hr).
1. Access: Menu > Service > Technician Access > Installer Setup.
2. Standard: Equipment config (stages, compressor type).
3. Advanced: Cycles (1-6), lockouts (5-70°F), airflow %, accessories (humidifier/UV/ERV).
4. Comfort: Dehumid overcool 0-3°F, response rate.
5. Reset: Equipment Defaults or Advanced Settings.
1. 1-Touch Presets: Home/Away/Sleep.
2. Aggressive Recovery: Disable 10-min inhibit for >2°F changes.
3. Air Cleaner: Auto/Quick/Allergy cycles.
4. Dehumidification: Blower airflow reduction up to 30%, overcool 1-3°F.
5. Humidification: With/without heat; steam adds 60-sec delay.
6. Dual Fuel: Balance point by comfort/cost/temp.
7. Weather/History: Forecast/radar; runtime/cycles logs.
Warning: Qualified personnel only. Disconnect power. Comply with codes.
Terminal Designations:
| Terminal | Description |
|---|---|
| R | 24 VAC Hot |
| B | Common |
| D | Data |
| RS | Remote Sensor |
| ODT | Outdoor Temp Sensor |
Notes: 3-wire (R/B/D) for communicating; max 500 ft. total. For 24V: Use Relay Panel. Ground unused wires; shielded cable optional.
Estimate monthly energy savings from zoning (assumes 0.3 kWh saved per daily zone adjustment; 30 days/month).