The Trane TZONE940AC52Z is a communicating sensor with display for Trane ComfortLink II zoning systems. It features a wall-mounted low-voltage control for zone temperature and humidity, compatible with the 950 Control (v2.2+). It displays indoor temperature, humidity, PM, schedule status, outdoor conditions, modes, setpoints, and fan control. It supports overrides and integrates for multi-zone efficiency. Below are the key specifications and operation instructions.
1. Mount Sensor: Follow installation; set zone address (hold INDOOR TEMP 5s).
2. Assign to Zone: On 950 Control: MENU > ZONES > SELECT ZONE > ZONE SENSOR > Assign address.
3. Customize Display: On 950: MENU > SETTINGS > SCREEN SETTINGS > ZONE SENSOR > Select options > APPLY.
4. Verify: Check signal icon; test modes/setpoints.
1. Display: Indoor temp/humidity/PM, schedule status, outdoor info, modes/setpoints, fan, icons (alerts/signal/notifications).
2. Controls: Cooling/Heating buttons for modes/setpoints (arrows adjust); Fan cycles options; Hold for overrides; Clean Screen activates safe mode.
3. Indicators: Triangle for critical alerts; signal bars for communication; hourglass for temporary holds.
1. Heat: Press Heating; adjust setpoint (red arrows); flame icon; overrides schedule temporarily.
2. Cool: Press Cooling; adjust setpoint (blue arrows); snowflake icon.
3. Auto: System-level via 950 Control.
4. Off: Via 950 Control.
5. Fan: Auto/On (system-wide; last sensor setting applies).
6. Schedule: Home/Away/Sleep displayed; follows 950 settings.
1. Access Setup: Hold INDOOR TEMP 5s; adjust SETUP NUMBER/SETTING (matrix in manual).
2. Overrides: Temporary (adjust, holds to next period); Hold Until (set end time); Permanent (indefinite).
3. Display Options: Via 950 Control: Temp scale, humidity display, etc.
4. Reset: Re-enter setup or power cycle via 950.
1. Zoning Integration: Communicates with 950 for multi-zone control; assigns to specific damper.
2. Alerts/Notifications: Critical (triangle: contact dealer); general (bell icon).
3. Communication: Data wire for real-time updates; signal strength indicator.
4. Clean Screen: Activates to safely clean display without damage.
Warning: Qualified personnel only. Disconnect power. Seal penetrations.
Terminal Designations:
| Terminal | Description |
|---|---|
| D | Data/Power |
| R | 24 VAC Hot |
| B | Common |
Notes: Route wires through base center; connect to terminals. Seal wall hole after wiring. Use with 950 Control v2.2+.
Estimate monthly energy savings from zoning (assumes 0.3 kWh saved per daily zone adjustment; 30 days/month).