The Trane TZON1050AC52ZA (ComfortLink™ II XL1050) is a Wi-Fi-enabled communicating connected control for advanced HVAC systems, supporting heat pump, heat/cool, dual fuel, and zoning configurations. It features a color touch screen, load-based staging, dehumidification/humidification/ventilation control, Trane Home integration, and diagnostic tools. It integrates with Trane/American Standard communicating equipment for multi-zone efficiency. Below are the key specifications and operation instructions.
1. Power Up: Connect to sub-base; wait 90-120 seconds for sequence.
2. User Wizard: Home > Menu > Settings > User Setup Wizard: Configure display, schedules.
3. Zoning Prep: Power zone panel, connect bus (D/B), address sensors, install dampers before enabling.
4. Firmware: Use USB from www.Trane.com/residential for updates.
1. Display: Current temp, mode, load values; touch for details.
2. Controls: Touch screen for modes/adjustments; Menu for settings/diagnostics.
3. Indicators: System status, alerts, zoning capacity.
1. Heat: Select Heat; load-based staging; humidification.
2. Cool: Select Cool; staging with dehumidification.
3. Off: No operation.
4. Auto: Changeover based on demand.
5. Emergency Heat: Aux heat bypass.
6. Fan: Auto/On/Auto (circulation).
7. Air Cleaner: Auto/On/Off.
1. Access: Menu > Settings: Groups for equipment, zoning, accessories, comfort, airflow, lockouts.
2. Comfort: Dehumidification enable, humidity targets, overcooling limit.
3. Airflow: Delays, CFM settings (variable speed auto).
4. Lockouts: Auxiliary/compressor based on outdoor temp.
5. Reset: Factory defaults via service menu.
1. Zoning: Multi-zone with dampers; auto/manual sizing; relief for excess air.
2. Dehumidification: Overcooling when RH high; fan with dehumidifier.
3. Humidifier/Ventilation: Timed or with system; continuous fan.
4. Dual Fuel: Balance point settings.
5. Diagnostics: Test modes (60 min max), summary tables.
Warning: Professional installation. Disconnect power. Comply with codes.
Terminal Designations (Communicating Bus):
| Terminal | Description |
|---|---|
| R | 24VAC Hot |
| C | Common |
| D | Data Bus |
| B | Bus Ground |
| AUX | Accessories (via Relay Panel) |
| ODT | Outdoor Temp Sensor |
| S1/S2 | Remote Sensors |
Notes: Use communicating bus (D/B) for units; Relay Panel for accessories. Do not bundle sensor wires with HVAC. Diagrams for indoor/outdoor, S9V2 furnace setups.
Estimate monthly energy savings from dehumidification overcooling (assumes 0.25 kWh saved per cycle; 30 days/month).