The Trane THS-02 is a digital thermostat designed for heat pump systems with 2 compressors and auxiliary heating. It provides precise control and display of ambient temperature, system status, and optional outdoor temperature (with sensor). Features include battery-free operation for setting retention, keyboard lock, micro-switch configurations for timing (2/4 min minimum), and power cut recovery. It supports compressor control, fan, reversing valve, and forced auxiliary heating ("EHt" display). Below are the key specifications and operation instructions.
1. Position Thermostat: Mount on indoor wall away from influences; no batteries required.
2. Power On: Connect to 24V supply; display activates with ambient temperature.
3. Configure Micro-Switches: Set for heat pump/auxiliary timing (see Settings).
4. Test Display: Verify ambient and optional outdoor temp.
1. Display: Ambient temperature and system status symbols; optional outdoor temp.
2. Controls: Press keys for mode selection, adjustments; symbols indicate functions.
3. Indicators: "EHt" for auxiliary heating (5 sec in forced mode); LEDs for status.
1. Heating (Heat Pump): Activates compressors 1/2; reversing valve for mode.
2. Auxiliary Heating: Engages for forced heat ("EHt" display); compressor may cease.
3. Cooling: Compressors 1/2 with reversing valve.
4. Fan: On with system or continuous.
5. Off: Stops all operations.
1. Micro-Switches: Access base for settings: heat pump normal/additional (compressor stop during aux), auxiliary 2/4 min min. operation, keyboard lock.
2. Outdoor Sensor: Connect for display; press key to view.
3. Reset: Power cycle for recovery; no manual reset detailed.
1. Power Cut Recovery: Retains settings without battery; resumes on restore.
2. Forced Auxiliary: Activates independently; display "EHt".
3. Timing Controls: Micro-switches for min. operation (2/4 min) to optimize efficiency.
4. Sensor Integration: Optional outdoor temp for monitoring.
Warning: Professional installation. Disconnect power. Ensure precise positioning for accuracy.
Supports heat pump with 2 compressors, auxiliary heating, fan, reversing valve. Use 20-30 VAC/24 VDC, 0.05-0.5A (peaks 1A).
| Terminal | Description |
|---|---|
| Compressor 1 | Cooling/heating output 1; 20-30 VAC/24 VDC, 0.05-0.5A |
| Compressor 2 | Cooling/heating output 2; same specs |
| Auxiliary | Make-up/forced aux heating; same specs |
| Fan | Fan starting; supplied separately |
| Reversing Valve | Mode switching; supplied separately |
| 24V(C) | Common |
| RS+V | Remote sensor/power (details limited) |
| LED1/LED2 | Indicators |
| CLK1/CLK2 | Clock functions |
Notes: Independent or mains power via 24V transformer. Optional outdoor sensor wiring.
Estimate monthly energy savings from 2/4 min operation timing (assumes 0.1 kWh saved per cycle with 4-min delay; 30 days/month).