The Trane TCONT824 (XL 824 Connected Control) is a programmable Wi-Fi thermostat for advanced heating and cooling systems. It features a touch screen display, support for up to 5 stages heat/2 stages cool, heat pump/dual fuel compatibility, enhanced dehumidification, humidifier/ventilation control, and Trane Home integration. It includes adaptive recovery, diagnostic tools, and configurable lockouts. Below are the key specifications and operation instructions.
1. Power Up: Connect to sub-base; initiates 90-120 second sequence.
2. User Wizard: Home > Menu > Settings > User Setup Wizard; follow prompts for configuration.
3. Wi-Fi Connect: Via wireless or wired RJ-45 for Trane Home features.
4. Installer Setup: Configure groups for accessories, comfort, airflow, lockouts.
1. Display: Current temperature, mode, alerts, status indicators.
2. Controls: Touch screen for mode selection, adjustments; Menu for settings/diagnostics.
3. Indicators: Alert codes, system on status, load values.
1. Heat: Select Heat; adjusts heating stages based on load.
2. Cool: Select Cool; activates cooling stages after thresholds.
3. Off: Select Off; system inactive.
4. Auto: Automatic changeover between heat/cool.
5. Emergency Heat: For heat pump aux heat bypass.
6. Fan: Auto (system demand), On (continuous).
1. Access: Menu > Settings; navigate groups with arrows.
2. Accessories: Filter type, humidifier (Powered/Bypass/Steam), ventilation (ERV/HRV).
3. Comfort: Dehumidification enable, overcool limit (0-3°F), response rate (Standard/Fast).
4. Airflow: Blower delays, continuous fan speeds.
5. Lockouts: Compressor/aux/furnace stages based on outdoor temp.
1. Dehumidification: Overcooling when humidity high; fan with dehumidifier.
2. Humidifier: Controls via Aux; operates on humidity setpoint.
3. Ventilation: Accumulates run time; outdoor overrides.
4. Diagnostics: Test modes (60 min max), system report for real-time data.
Warning: Professional installation. Disconnect power. Comply with codes.
Terminal Designations:
| Terminal | Description |
|---|---|
| R | 24VAC Hot |
| C | Common |
| Y/Y1 | 1st Stage Cooling/Compressor |
| Y2 | 2nd Stage Cooling |
| W/W1 | 1st Stage Heating/Aux Heat |
| W2 | 2nd Stage Heating |
| G | Fan |
| O | Reversing Valve (Cooling) |
| B | Reversing Valve (Heating) |
| AUX1/AUX2 | Accessories (Humidifier/Ventilation) |
| X1/X2 | Optional Sensors |
Notes: Specific diagrams for Heat/Cool (Pages 6-15), Heat Pump (16-22), Dual Fuel (23-25). Y required at indoor; remove jumpers (e.g., BK at S9V2). Do not bundle X1/X2 wires.