Trane TCONT824 Thermostat Operation Manual

The Trane TCONT824 (XL 824 Connected Control) is a programmable Wi-Fi thermostat for advanced heating and cooling systems. It features a touch screen display, support for up to 5 stages heat/2 stages cool, heat pump/dual fuel compatibility, enhanced dehumidification, humidifier/ventilation control, and Trane Home integration. It includes adaptive recovery, diagnostic tools, and configurable lockouts. Below are the key specifications and operation instructions.

1. Key Specifications 2. Operation Instructions 2.1. Initial Setup 2.2. Home Screen Navigation 2.3. Operating Modes 2.4. Settings Screen 2.5. Advanced Features 2.6. Troubleshooting 3. Installation Instructions 3.1. Pre-Installation 3.2. Wiring Diagrams 3.3. Configuration Options 4. Calculation Tool

Key Specifications

Operation Instructions

Initial Setup

1. Power Up: Connect to sub-base; initiates 90-120 second sequence.
2. User Wizard: Home > Menu > Settings > User Setup Wizard; follow prompts for configuration.
3. Wi-Fi Connect: Via wireless or wired RJ-45 for Trane Home features.
4. Installer Setup: Configure groups for accessories, comfort, airflow, lockouts.

Home Screen Navigation

1. Display: Current temperature, mode, alerts, status indicators.
2. Controls: Touch screen for mode selection, adjustments; Menu for settings/diagnostics.
3. Indicators: Alert codes, system on status, load values.

Operating Modes

1. Heat: Select Heat; adjusts heating stages based on load.
2. Cool: Select Cool; activates cooling stages after thresholds.
3. Off: Select Off; system inactive.
4. Auto: Automatic changeover between heat/cool.
5. Emergency Heat: For heat pump aux heat bypass.
6. Fan: Auto (system demand), On (continuous).

Settings Screen

1. Access: Menu > Settings; navigate groups with arrows.
2. Accessories: Filter type, humidifier (Powered/Bypass/Steam), ventilation (ERV/HRV).
3. Comfort: Dehumidification enable, overcool limit (0-3°F), response rate (Standard/Fast).
4. Airflow: Blower delays, continuous fan speeds.
5. Lockouts: Compressor/aux/furnace stages based on outdoor temp.

Advanced Features

1. Dehumidification: Overcooling when humidity high; fan with dehumidifier.
2. Humidifier: Controls via Aux; operates on humidity setpoint.
3. Ventilation: Accumulates run time; outdoor overrides.
4. Diagnostics: Test modes (60 min max), system report for real-time data.

Troubleshooting

Installation Instructions

Warning: Professional installation. Disconnect power. Comply with codes.

Pre-Installation

Wiring Diagrams

Terminal Designations:

TerminalDescription
R24VAC Hot
CCommon
Y/Y11st Stage Cooling/Compressor
Y22nd Stage Cooling
W/W11st Stage Heating/Aux Heat
W22nd Stage Heating
GFan
OReversing Valve (Cooling)
BReversing Valve (Heating)
AUX1/AUX2Accessories (Humidifier/Ventilation)
X1/X2Optional Sensors

Notes: Specific diagrams for Heat/Cool (Pages 6-15), Heat Pump (16-22), Dual Fuel (23-25). Y required at indoor; remove jumpers (e.g., BK at S9V2). Do not bundle X1/X2 wires.

Configuration Options

  1. Mount sub-base; connect wires per diagram.
  2. Power up for sequence; access Installer Setup via Menu.
  3. Configure groups: Accessories, Comfort, Airflow, Lockouts.
  4. USB/Wi-Fi setup: Download from Trane site; enter Dealer Code.
  5. Test: Use diagnostic tools for stages, fan, alerts.

Calculation Tool

Estimate monthly energy savings from enhanced dehumidification (assumes 0.25 kWh saved per overcool cycle; 30 days/month).





Trane Thermostat Manual© - All Rights Reserved 2025