The Trane TCONT802AS32DAA (TCONT802AS32DA) is a touch screen programmable thermostat for 24 Vac heating and cooling systems. It features a large touch screen display, menu-driven programming, Adaptive Intelligent Recovery, support for 1-2 stage heat/cool and heat pump systems, remote sensor compatibility, and fan circulation mode. It supports automatic/manual changeover, compressor protection, and customizable cycles per hour. Below are the key specifications and operation instructions.
1. Power On: Ensure 24 Vac common connected; display activates.
2. Set Calendar: Access Installer Setup to set time and day for memory retention.
3. Configure System: Use Installer Setup Menu to match heating/cooling system type and stages.
4. Set Defaults: System to Heat, Fan to Auto.
1. Display: Current temperature, system status (Heat/Off/Cool/Auto/Em. Heat), fan status (On/Auto/Circ), setpoints.
2. Controls: Touch screen for mode selection, temperature adjustments; menu for programming.
3. Indicators: System on status, temperature limits.
1. Heat: Select Heat; adjust setpoint up; activates heating after delay.
2. Cool: Select Cool; adjust setpoint down; activates cooling after lockout.
3. Off: Select Off; no heating/cooling.
4. Auto: Automatic changeover with 3°F deadband.
5. Em. Heat: For heat pumps; bypasses compressor.
6. Fan: On (continuous), Auto (with system), Circ (periodic circulation).
1. Access Menu: Press and hold blank keys for Installer Setup; navigate options.
2. Cycles per Hour: Set 1-12 for heat/cool stages.
3. Deadband: 2-9°F between setpoints (default 3°F).
4. Changeover: Auto or Manual.
5. Reset: Power cycle or reconfigure menu.
1. Adaptive Recovery: Starts system early to reach setpoint by program time.
2. Sensor Selection: Indoor or outdoor remote sensor; stabilizes in 5 min.
3. Compressor Lockout: 5-35°F below balance point.
4. Programming: Menu-driven with multiple day selection.
Warning: Professional installation by trained personnel. Disconnect power.
Terminal Designations (varies by system):
| Terminal | Description |
|---|---|
| R/Rc | 24V Power |
| B | Common (24 Vac) |
| W1/W2 | Heat Stages/Aux |
| Y1/Y2 | Cool/Compressor Stages |
| G | Fan |
| O/B | Reversing Valve (Heat Pump) |
| E | Emergency Heat |
Notes: Separate cable for outdoor sensor. Factory jumper on X2/B. See diagrams for conventional/heat pump, single/multi-stage. Tighten screws; push wires into wall.
Estimate monthly energy savings from Adaptive Intelligent Recovery (assumes 0.15 kWh saved per recovery cycle; 30 days/month).