The Trane TCONT600AF11MA is a programmable comfort control thermostat for heating and cooling systems, including heat pumps with auxiliary heat. It features a large, clear backlit LCD display, pre-programmed Energy Star schedules for up to 33% energy savings, and Adaptive Intelligent Recovery (AIR) to reach target temperatures on time. It supports Auto Changeover for dual heating/cooling systems and includes compressor protection. Below are the key specifications and operation instructions.
1. Set Time and Day: Press SET CLOCK button, adjust time with up/down arrows, press SET DAY, select day, press RUN to save.
2. Select Fan Setting: Press FAN button to choose Auto or On (preset: Auto).
3. Select System Setting: Press SYSTEM button to choose Heat, Cool, Off, or Auto (preset: Heat).
4. Verify or Adjust Program Schedules: Pre-set to Energy Star levels (e.g., Heat Mon-Fri: Wake 6:00 AM/70°F, Leave 8:00 AM/62°F); adjust if needed via SET SCHEDULE.
5. Install Batteries (Optional): For backup power to maintain settings during outages.
1. Display Elements: Current inside temperature, time/day, temperature setting, program period (Wake/Leave/Return/Sleep), system mode, fan setting, icons for Recovery, Auxiliary Heat, Low Battery.
2. Key Functions: SYSTEM (Heat/Cool/Off/Auto), FAN (Auto/On), SET SCHEDULE (edit programs), HOLD (temporary/permanent override), SET CLOCK/DAY (time/day), RUN (exit programming).
3. Adjustments: Up/down arrows for temperature; hold for permanent changes.
4. Backlight: Activates on key press; auto-off after inactivity.
1. Edit Schedule: Press SET SCHEDULE, select day (Mon-Fri or Sat-Sun), set time and temperature for each period (Wake/Leave/Return/Sleep) using arrows and NEXT button, press DONE to save.
2. Cancel Period: In SET SCHEDULE > Period > Cancel Period.
3. Presets: Pre-set Energy Star schedules (e.g., Heat Mon-Fri: Wake 6:00 AM/70°F, Leave 8:00 AM/62°F, Return 5:00 PM/70°F, Sleep 10:00 PM/62°F; similar for Cool and weekends).
4. Holds: Press HOLD for temporary override (until next period) or permanent (hold again to resume); Vacation mode for multi-day holds.
5. Recovery: Adaptive Intelligent Recovery (AIR) starts system early to reach setpoint exactly at schedule time; displays "Recovery".
1. Fan: Press FAN for Auto (runs only with system) or On (continuous).
2. System: Press SYSTEM for Heat (heating only), Cool (cooling only), Off (both off), Auto (switches based on temperature).
3. Auto Changeover: In Auto mode, heat/cool settings must differ by at least 3°F; deadband adjustable in advanced setup.
4. Hold: Press HOLD, adjust temperature; resumes schedule when pressed again.
5. Clock: Press SET CLOCK/DAY for time/day adjustments.
1. Temporary Override: Press HOLD, adjust temperature; reverts at next period.
2. Permanent Hold: Overrides all periods until manually canceled.
3. Compressor Protection: Automatic delay before restart to prevent damage.
4. Adaptive Intelligent Recovery (AIR): Learns heating/cooling time; displays "In Recovery" when pre-heating/cooling.
5. Auto Changeover: Automatically switches between Heat and Cool based on indoor temperature.
6. Auxiliary Heat: Indicator for heat pumps; activates when needed.
Warning: Professional installation required. Do not operate cooling below 50°F (10°C) outdoor temperature to prevent compressor damage. For full installation, consult a trained technician.
Wiring diagrams are not included in the owner's manual. Professional wiring for 24 VAC systems is required. Contact your HVAC contractor for installation details, including connections for heat/cool, heat pump with auxiliary heat, and fan control. Ensure C-wire is connected for power.
Estimate monthly energy savings from Energy Star scheduling (assumes 1% savings per °F setback; 30 days/month).