The Trane TCONT203AS42MA (XR203 Programmable Thermostat) is a 7-day or 5-1-1 programmable thermostat for two-stage 2H/1C heat/cool systems. It features a 3.5-inch backlit LCD display, energy-saving factory schedules with four periods per day (Wake, Leave, Return, Sleep), and adaptive intelligent recovery to reach programmed temperatures on time. Compatible with gas/oil/electric systems, it includes compressor lockout (5-minute minimum off time), air filter reminders, keypad lock, and battery backup. Below are the key specifications and operation instructions.
1. Install Batteries: Pull thermostat from wallplate; insert two AA alkaline batteries (observe polarity). Snap back on. Remove battery tag if present.
2. Set Time: Press Set Time; adjust hour/minute with arrows; press Next for day; press Exit.
3. Set Schedule: Defaults to Energy Star 5-1-1; press Sched > Edit to customize.
4. System Mode: Press System for Auto/Heat/Off/Cool.
5. Fan Mode: Press Fan for Auto/On.
1. Display: Inside temp, set temp, mode, fan, schedule (Following/Hold), clock, day.
2. Keys: Fan (Auto/On), System (modes), Sched (scheduling), Hold (overrides), Clock (time), Screen (cleaning lock), More (outdoor temp/humidity/timers).
3. Adjustments: Arrows for temp; hold for permanent hold.
4. Cleaning: Press Screen to lock keys for 30s.
1. Edit Schedule: Sched > Edit > Select days > Period (Wake/Leave/Return/Sleep) > Set time/heat/cool/fan > Done.
2. Cancel Period: Sched > Edit > Period > Cancel Period.
3. Presets: Sched > Preset > Comfort/Energy Star > Yes to load.
4. Holds: Arrows for temp hold until next period; Hold for permanent; Vacation for days.
5. Recovery: Adaptive: Starts early to reach setpoint (shows "Recovery").
1. Access Advanced: System (blank keys) > Center key (hold 5s) > "User Setup" > Up arrow to scroll.
2. Options: 0120: Year; 0130: Month; 0140: Day of week; 0150: Date; 0160: Time; 0330: DST (0/1); 0510: Humidifier timer; 0640: Time format (12/24).
3. Reminders: More > Edit > Set filter/UV/humidifier days.
4. Humidity: Arrows for dehum setpoint (select models).
5. Locking: Partial (specific keys) or Full (all); unlock via Advanced.
1. Humidity/Dehum: Displays RH; set dehum setpoint (AC runs longer if high).
2. Reminders: Filter/UV/humidifier; reset via More > Reset.
3. Adaptive Recovery: Learns over 1 week; no aux heat during recovery.
4. Outdoor Temp: More key (with sensor).
Warning: Professional installation. Disconnect power.
Terminal Designations:
| Terminal | Description |
|---|---|
| R/RH (4-M-R5) | 24V Power (Heating) |
| R/RC-V | 24V Power (Cooling) |
| W/H-4 | Heating Relay |
| G-F | Fan Relay |
| Y-Y6 | Cooling Relay |
| O | Reversing Valve (Cool mode, HP only) |
| B | Reversing Valve (Heat mode, HP only) |
Notes: Wire condensate switches between Y and Y1. X2 for aux during defrost. Remove jumper for 2-transformer RC/RH. Add for HP. Clip W905 for hydronic.
Estimate monthly energy savings from scheduling (assumes 1% savings per °F setback; 30 days/month).