Trane TCONT202AS11MA Thermostat Operation Manual

The Trane TCONT202AS11MA (XR202) is a programmable 1H/1C digital thermostat for residential heating and cooling systems. It features a 3.5-inch backlit display, 7-day/5-1-1/non-programmable scheduling, early start option, and compatibility with Trane systems like TAM7/TAM9, GAF2-S, and S9V2 furnaces. It supports compressor lockout (5-min delay), cycle rate adjustments, air filter reminder, keypad lock, and °F/°C selection. Below are the key specifications and operation instructions.

1. Key Specifications 2. Operation Instructions 2.1. Initial Setup 2.2. Home Screen Navigation 2.3. Operating Modes 2.4. Settings Screen 2.5. Advanced Features 2.6. Troubleshooting 3. Installation Instructions 3.1. Pre-Installation 3.2. Wiring Diagrams 3.3. Configuration Options 4. Calculation Tool

Key Specifications

Operation Instructions

Initial Setup

1. Install Batteries: Remove thermostat from sub-base; insert two AA alkaline batteries (observe polarity). Snap back on. Remove battery tag.
2. Set Time/Day: Press Set Time; adjust hour/minutes/day with arrows and Next; press Exit.
3. Set Schedule Type: Via User Menu item 01 (7-day/5-1-1/non-programmable).
4. Configure: See Settings for °F/°C, adjustment, backlight.

Home Screen Navigation

1. Display: Room temperature, setpoint, time, day, mode icons, battery status, alerts.
2. Controls: Up/Down arrows for adjustments; System switch (Heat/Cool/Off); Fan (Auto/On); Menu for settings; Hold/Run for overrides.
3. Indicators: Low battery, "Heat On"/"Cool On", "Starting Soon" (lockout), "Call for Service".

Operating Modes

1. Heat: System to Heat; raise setpoint; "Heat On" after delay.
2. Cool: System to Cool; lower setpoint; "Cool On" after 5-min delay.
3. Off: System to Off; no operation.
4. Fan: Auto (with system) or On (continuous).
5. Overrides: Temporary (arrows, reverts in 2 hrs); Permanent Hold (Hold button).

Settings Screen

1. User Menu: Press Menu > Settings; adjust schedule type, early start, °F/°C, temp adj (±5°F), backlight, filter reminder.
2. Installer Menu: Hold Menu 8s; set cycle rates, lockout, limits, etc.
3. Keypad Lock: Hold Up + Menu; unlock after 3s.
4. Reset: Hold Menu + Backlight for schedule reset; remove batteries 2 min for full.

Advanced Features

1. Programming: Menu > Schedule; set times/temps for P1-P4 periods per day/mode.
2. Battery Life: Replace annually or on low indicator; preserves clock with C-wire.
3. Early Start: Menu option to reach setpoint by program time.
4. Filter Reminder: Set 1-12 months; "Change Filter" displays.

Troubleshooting

Installation Instructions

Warning: Professional installation. Disconnect power.

Pre-Installation

Wiring Diagrams

Terminal Designations:

TerminalDescription
Rc/Rh24V Power (jumpered; clip if separate)
WHeating Relay
GFan Relay
YCooling/Compressor Relay
O/BReversing Valve (Heat Pump)
CCommon (optional for backlight)

Notes: GAS/ELEC switch for system type; O/B for changeover (O default). Jumper Y-W for single-stage HP. Wire condensate switches between Y and Y1. See diagrams for specific systems (e.g., TAM7/TAM9, S9V2).

Configuration Options

  1. Mount sub-base level; connect wires per diagram.
  2. Set GAS/ELEC and O/B switches; install jumpers as needed.
  3. Snap thermostat on; remove battery tag.
  4. Access Installer Menu: Configure cycle rates, lockout, schedule, etc.
  5. Test: Fan, heat (1°F raise), cool (1°F lower, >55°F outdoor).

Calculation Tool

Estimate monthly energy savings from 5-1-1 scheduling (assumes 8°F setback saving 0.2 kWh per hour unoccupied; 30 days/month).