The Trane TCONT202 (XR202) is a programmable 1H/1C digital thermostat for residential heating and cooling systems. It features a 3.5-inch backlit display, 7-day/5-1-1/non-programmable scheduling, early start option, and compatibility with Trane systems like TAM7/TAM9, GAF2-S, and S9V2 furnaces. It supports compressor lockout (5-min delay), cycle rate adjustments, air filter reminder, keypad lock, and °F/°C selection. Below are the key specifications and operation instructions.
1. Install Batteries: Remove thermostat from sub-base; insert two AA alkaline batteries (observe polarity). Snap back on. Remove battery tag.
2. Set Time/Day: Press Set Time; adjust hour/minutes/day with arrows and Next; press Exit.
3. Set Schedule Type: Via User Menu item 01 (7-day/5-1-1/non-programmable).
4. Configure: See Settings for °F/°C, adjustment, backlight.
1. Display: Room temperature, setpoint, time, day, mode icons, battery status, alerts.
2. Controls: Up/Down arrows for adjustments; System switch (Heat/Cool/Off); Fan (Auto/On); Menu for settings; Hold/Run for overrides.
3. Indicators: Low battery, "Heat On"/"Cool On", "Starting Soon" (lockout), "Call for Service".
1. Heat: System to Heat; raise setpoint; "Heat On" after delay.
2. Cool: System to Cool; lower setpoint; "Cool On" after 5-min delay.
3. Off: System to Off; no operation.
4. Fan: Auto (with system) or On (continuous).
5. Overrides: Temporary (arrows, reverts in 2 hrs); Permanent Hold (Hold button).
1. User Menu: Press Menu > Settings; adjust schedule type, early start, °F/°C, temp adj (±5°F), backlight, filter reminder.
2. Installer Menu: Hold Menu 8s; set cycle rates, lockout, limits, etc.
3. Keypad Lock: Hold Up + Menu; unlock after 3s.
4. Reset: Hold Menu + Backlight for schedule reset; remove batteries 2 min for full.
1. Programming: Menu > Schedule; set times/temps for P1-P4 periods per day/mode.
2. Battery Life: Replace annually or on low indicator; preserves clock with C-wire.
3. Early Start: Menu option to reach setpoint by program time.
4. Filter Reminder: Set 1-12 months; "Change Filter" displays.
Warning: Professional installation. Disconnect power.
Terminal Designations:
| Terminal | Description |
|---|---|
| Rc/Rh | 24V Power (jumpered; clip if separate) |
| W | Heating Relay |
| G | Fan Relay |
| Y | Cooling/Compressor Relay |
| O/B | Reversing Valve (Heat Pump) |
| C | Common (optional for backlight) |
Notes: GAS/ELEC switch for system type; O/B for changeover (O default). Jumper Y-W for single-stage HP. Wire condensate switches between Y and Y1. See diagrams for specific systems (e.g., TAM7/TAM9, S9V2).
Estimate monthly energy savings from 5-1-1 scheduling (assumes 8°F setback saving 0.2 kWh per hour unoccupied; 30 days/month).