The Trane TCONT102 (XR102) is a non-programmable 1H/1C digital thermostat for residential heating and cooling systems. It features a 2-inch digital display, simultaneous heating/cooling setpoint storage, and compatibility with Trane systems like TAM7/TAM9, GAF2-S, and S9V2 furnaces. It supports temperature display adjustment (±3°F), °F/°C convertibility, low battery indicator, and a 5-minute compressor cycle-off delay. Below are the key specifications and operation instructions.
1. Install Batteries: Pull thermostat from wallplate; insert two AAA alkaline batteries (observe polarity). Snap back on. Remove battery tag if present.
2. Set System Mode: SYSTEM switch to Heat/Cool/Off.
3. Adjust Temperature: Up/Down arrows for setpoint.
4. Configure Display: See Settings for °F/°C, adjustment, backlight.
1. Display: Room temperature (default); press setpoint for "Set" view.
2. Controls: Up/Down arrows for adjustments; SYSTEM for modes; FAN for Auto/On.
3. Indicators: Low battery ("Change Bat"), compressor lockout (flashing snowflake), mode icons.
1. Heat: SYSTEM to Heat; raise setpoint; flame icon.
2. Cool: SYSTEM to Cool; lower setpoint; snowflake icon (non-flashing).
3. Off: SYSTEM to Off; no icons.
4. Fan: Auto (with system) or On (continuous).
1. °F/°C Convert: SYSTEM to Off; clip W904 jumper on circuit board for °C.
2. Temperature Adjustment: SYSTEM to Off; press Up/Down simultaneously 2s; adjust ±3°F with arrows; move SYSTEM switch to exit.
3. Backlight: SYSTEM to Heat; press Up/Down simultaneously 2s ("-L FF"); Up/Down for ON; SYSTEM to Off to exit.
4. Hydronic Adjustment: Clip W905 jumper for longer heating cycles.
5. Reset: SYSTEM to Off; press Up/Down simultaneously while switching to Heat.
1. Compressor Protection: 5-min off delay; flashing snowflake during lockout.
2. Battery Life: Replace annually or when "Change Bat" appears.
3. Electric/Gas Switch: Gas for gas/electric; Electric for electric heat.
Warning: Professional installation. Disconnect power.
Terminal Designations:
| Terminal | Description |
|---|---|
| R/RH (4-M-R5) | 24V Power (Heating) |
| R/RC-V | 24V Power (Cooling) |
| W/H-4 | Heating Relay |
| G-F | Fan Relay |
| Y-Y6 | Cooling Relay |
| O | Reversing Valve (Cool mode, HP only) |
| B | Reversing Valve (Heat mode, HP only) |
Notes: Wire condensate switches between Y and Y1. X2 for aux during defrost. Remove jumper for 2-transformer RC/RH. Add for HP. Clip W905 for hydronic.
Estimate monthly energy savings from compressor delay (assumes 0.3 kWh saved per 5-min delay; 30 days/month).