The Trane TAYSTAT 570 is an electronic heat-pump thermostat designed for 24 VAC heat pump systems, including single- and multi-stage configurations with auxiliary heat. It features a simple LCD display for room temperature and setpoints, system modes (Em. Ht., Heat, Off, Auto, Cool), and fan options (Auto, On) for reliable control. Automatic changeover and emergency heat capabilities ensure comfort, with warnings for equipment protection. Below are the key specifications and operation instructions.
1. Power On: After installation, the display shows room temperature; all segments briefly illuminate.
2. Set System Mode: Use SYSTEM switch: Em. Ht. (emergency), Heat, Off, Auto, Cool.
3. Set Fan Mode: Use FAN switch: Auto (with system) or On (continuous).
4. Adjust Temperature: Press Increase/Decrease keys; setpoint displays with "Set" indicator.
1. Display: Room temperature (default); press setpoint key to toggle "Set" view; indicator points to Room/Set.
2. Controls: SYSTEM/FAN switches; Increase/Decrease for adjustments; Information (i) key for thermostat info (revision, code).
3. Indicators: Dynamic labels; caution for cooling below 50°F.
1. Emergency Heat (Em. Ht.): Bypasses compressor; activates auxiliary heat.
2. Heat: Engages compressor/auxiliary; raise setpoint.
3. Cool: Engages compressor; lower setpoint (avoid below 50°F).
4. Auto: Switches modes with 3°F deadband.
5. Off: Inactive.
6. Fan: Auto or On.
1. Access Installer Setup: Hold Increase 5s; scrolls options (01-08).
2. Key Options: 01: Scale (°F/°C); 02/03: Extended fan (heating/cooling On/Off); 04: Changeover (Auto/Manual); 05: Compressor off time (3/5/10/15 min); 06: Temp adjustment (±3°F); 07: Clock accuracy (±15 min/year); 08: Aux heat type (0=None, 1=Gas, 2=Electric).
3. Exit: Press i or timeout (5 min).
1. System Test: Hold Increase 10s; tests stages (fan, heat 1-3, Em. Ht., cool 1-2).
2. Outdoor Sensor: Optional for lockout.
3. Aux Heat: Up to 3 stages; type configurable.
4. Extended Fan: Post-cycle run (On/Off).
Warning: Technician only. Disconnect power.
Two-compressor heat pump with aux heat:
| Terminal | Connection |
|---|---|
| R | 24V Hot |
| B | Common |
| Y1 | Compressor 1 |
| Y2 | Compressor 2 |
| O | Changeover (Cool) |
| W/AUX | Aux Heat 1 |
| E | Emergency Heat |
| G | Fan |
| AUX2 | Aux Heat 2 |
| AUX3 | Aux Heat 3 |
| S1/S2 | Outdoor Sensor |
Note: Single compressor: Down-select Y2.
Estimate monthly savings from aux heat lockout (0.4 kWh/hr avoided; 5°F threshold; 30 days/month).