The Trane TAYSTAT 380 is a multistage electronic thermostat providing control for 24 VAC two-stage heating and two-stage cooling systems. It requires a common wire for power and supports automatic changeover with fan operation in heat mode. Ideal for residential applications, it features an LCD display for easy setpoint adjustments and system status. Below are the key specifications and operation instructions.
1. Power On: After installation, apply power; display shows room temperature.
2. Set System Mode: Press System key to cycle Heat, Off, Cool, Auto.
3. Set Fan Mode: Press Fan key to cycle On, Auto.
4. Adjust Temperature: Use keyboard (up/down arrows) for setpoints.
1. Display: Shows room temperature, setpoints, mode status.
2. Controls: System key for modes; Fan key for fan; keyboard for adjustments.
3. Indicators: Dynamic labels for functions.
1. Heat: System to Heat; raise setpoint.
2. Cool: System to Cool; lower setpoint.
3. Auto: Switches heat/cool with 3°F deadband.
4. Off: System inactive.
5. Fan: Auto with system; On continuous.
1. Access Installer Setup: Hold Increase/Decrease 3s; displays setup number.
2. Fan Operation: Setup 1: Conventional (equipment controls fan) or Thermostat (controls fan).
3. Deadband: Setup 2: Minimum 3°F between heat/cool (default).
4. Exit: Timeout after 5 min or advance through options.
1. Installer System Test: Hold Increase/Decrease until 00; advance with Increase for tests (e.g., fan, stages).
2. Compressor Protection: Bypassed in test mode.
3. Changeover: Automatic in Auto mode.
Warning: Trained technician only. Disconnect power before wiring.
For multistage heating/cooling:
| Terminal | Connection |
|---|---|
| R | 24V Power |
| B | Common |
| W1 | Heat Stage 1 |
| W2 | Heat Stage 2 |
| Y1 | Cool Stage 1 |
| Y2 | Cool Stage 2 |
| G | Fan |
Note: Pull wires through wallplate; secure with screws.
Estimate monthly savings from deadband (assumes 0.3 kWh per °F per hour; 3°F min; 30 days/month).