The Trane TAYSTAT 375 is a multistage electronic thermostat providing control for 24 VAC two-stage heating and two-stage cooling systems. It requires a common wire for power and supports automatic changeover with fan operation in heat mode. Ideal for residential applications, it features an LCD display for easy setpoint adjustments and system status. Below are the key specifications and operation instructions.

1. Key Specifications 2. Operation Instructions 2.1. Initial Setup 2.2. Home Screen Navigation 2.3. Operating Modes 2.4. Settings Screen 2.5. Advanced Features 2.6. Troubleshooting 3. Installation Instructions 3.1. Pre-Installation 3.2. Wiring Diagrams 3.3. Configuration Options 4. Calculation Tool

Key Specifications

Operation Instructions

Initial Setup

1. Power On: After installation, apply power; display shows room temperature.
2. Set System Mode: Press System key to cycle Heat, Off, Cool, Auto.
3. Set Fan Mode: Press Fan key to cycle On, Auto.
4. Adjust Temperature: Use keyboard (up/down arrows) for setpoints.

Home Screen Navigation

1. Display: Shows room temperature, setpoints, mode status.
2. Controls: System key for modes; Fan key for fan; keyboard for adjustments.
3. Indicators: Dynamic labels for functions.

Operating Modes

1. Heat: System to Heat; raise setpoint.
2. Cool: System to Cool; lower setpoint.
3. Auto: Switches heat/cool with 3°F deadband.
4. Off: System inactive.
5. Fan: Auto with system; On continuous.

Settings Screen

1. Access Installer Setup: Hold Increase/Decrease 3s; displays setup number.
2. Fan Operation: Setup 1: Conventional (equipment controls fan) or Thermostat (controls fan).
3. Deadband: Setup 2: Minimum 3°F between heat/cool (default).
4. Exit: Timeout after 5 min or advance through options.

Advanced Features

1. Installer System Test: Hold Increase/Decrease until 00; advance with Increase for tests (e.g., fan, stages).
2. Compressor Protection: Bypassed in test mode.
3. Changeover: Automatic in Auto mode.

Troubleshooting

Installation Instructions

Warning: Trained technician only. Disconnect power before wiring.

Pre-Installation

Wiring Diagrams

For multistage heating/cooling:

TerminalConnection
R24V Power
BCommon
W1Heat Stage 1
W2Heat Stage 2
Y1Cool Stage 1
Y2Cool Stage 2
GFan

Note: Pull wires through wallplate; secure with screws.

Configuration Options

  1. Hold Increase/Decrease 3s for Installer Setup.
  2. Set fan operation (Setup 1).
  3. Set deadband (Setup 2, min 3°F).
  4. Run system test (hold to 00, advance).

Calculation Tool

Estimate monthly savings from deadband (assumes 0.3 kWh per °F per hour; 3°F min; 30 days/month).