The Trane TAYSTAT 370 is an electronic low-voltage thermostat for residential heating and cooling systems, providing simple control for conventional and heat pump configurations. It features a large digital LCD display for room temperature and setpoints, with system modes (Heat, Cool, Off, Auto) and fan options (Auto, On). No batteries required, it supports automatic changeover in Auto mode with a minimum 3°F deadband. Below are the key specifications and operation instructions.
1. Power On: After installation, the display shows the current room temperature.
2. Set System Mode: Use the SYSTEM switch to select Heat, Cool, Off, or Auto.
3. Set Fan Mode: Use the FAN switch to select Auto or On.
4. Adjust Temperature: Use the up/down arrows to set the desired temperature.
1. Display: Shows current room temperature with a room indicator; setpoints adjustable via arrows.
2. Controls: SYSTEM switch for modes; FAN switch for fan; arrows for temperature.
3. Indicators: Visual feedback for temperature changes and mode status.
1. Heat Mode: SYSTEM to Heat; adjust setpoint above room temp.
2. Cool Mode: SYSTEM to Cool; adjust setpoint below room temp.
3. Auto Mode: SYSTEM to Auto; switches between heat/cool with 3°F deadband.
4. Off Mode: SYSTEM to Off; system inactive.
5. Fan: Auto (runs with system) or On (continuous).
1. System and Fan: Controlled via bottom switches on thermostat.
2. Temperature Display: Shows room temperature; adjust with arrows.
3. Deadband: Fixed at 3°F in Auto mode (no user adjustment).
4. Exit: Changes take effect immediately.
1. Auto Changeover: Automatically selects heat or cool based on setpoints.
2. Temperature Adjustment: Visual indicators show changes; prevents equipment damage.
3. Compressor Protection: Built-in delays to avoid short cycling.
Warning: Professional installation required. Disconnect power before wiring to avoid injury.
For single-stage conventional (Gas/Electric):
| Terminal | Connection |
|---|---|
| R | 24V Power (Red) |
| W | Heat (White) |
| Y | Cool (Yellow) |
| G | Fan (Green) |
| C | Common (Blue) |
Note: For heat pump, add O/B for reversing valve; jumper R/Rc if single transformer.
Estimate monthly energy savings from Auto mode deadband (assumes 0.3 kWh per °F per hour; 3°F fixed deadband; 30 days/month).