Trane Schlage Link TZEMT400BB32MAA Thermostat Operation Manual

The Trane Schlage Link TZEMT400BB32MAA is a Z-Wave enabled thermostat for controlling heating and cooling HVAC systems. It provides typical thermostat control with Z-Wave™ RF communications for remote access via Schlage LiNK™ integration. Features include a graphical LCD display, 7-day programmable scheduling with 4 periods per day, energy-saving modes, and compatibility with single/multistage forced air systems. Below are the key specifications and operation instructions.

1. Key Specifications 2. Operation Instructions 2.1. Initial Setup 2.2. Home Screen Navigation 2.3. Scheduling and Presets 2.4. Settings Screen 2.5. Advanced Features 2.6. Troubleshooting 3. Installation Instructions 3.1. Pre-Installation 3.2. Wiring Diagrams 3.3. Configuration Options 4. Calculation Tool

Key Specifications

Operation Instructions

Initial Setup

1. Set the Clock: Press MENU, scroll to User Settings, select Set Clock. Adjust hour, minute, AM/PM, month, day, year, and day of week using +/− buttons, then press Set to save.
2. Calibrate Sensor: MENU > User Settings > Sensor Calibration (±7°F).
3. Enable Scheduling: In Installer Settings > System Settings > Sched Enable (Y to enable).
4. Z-Wave Integration: Perform inclusion (see Advanced Features).
5. Set Initial Mode: Press Mode for Off/Heat/Cool/Auto; Fan for Auto/On.
6. Adjust Setpoints: Use Up/Down buttons (maintains 3°F minimum separation).

Home Screen Navigation

1. Display: Clock (upper left; blinks if unset), ambient temperature, heat/cool setpoints, system status (e.g., Sys Off, Run, Filter), dynamic labels above/below 6 buttons.
2. Function Control Buttons:
ButtonDescription
MenuAccess menus (User Settings, Usage Graph, ESM Setpoints, ZWave Install, Thermostat Info, Installer Settings [hidden], Schedules [disabled by default])
System ModeChange to Off (system off), Heating (heating only), Cooling (cooling only), Auto (heating/cooling as needed)
Fan ModeChange to Auto (fan on when heating/cooling needed) or On (fan constant)
Schedule ModeChange to Hold (maintain current setpoints, ignore schedules), Run (follow schedule or Z-Wave schedule), Energy Saving Mode (use ESM setpoints)
3. Setpoint Adjustment: Up/Down buttons adjust temperatures; press buttons to navigate; labels change dynamically.
4. Minimized Display Mode: Shows only temperature after timeout (see Settings).

Scheduling and Presets

Scheduling is disabled by default (controlled by Z-Wave); enable in Installer Settings (Sched Enable: Y). Supports 4 periods per day (Wake, Day, Eve, Sleep) for 7 days, with separate heat/cool setpoints. 1. Enable/Disable Schedules: In Installer Settings > System Settings > Sched Enable (Y to enable, N to disable).
2. Load Preset Schedule: Press MENU > Schedules > Select Heat and Cool or Preset. Choose Preset: Comfort (mild setbacks) or Energy Star (deeper setbacks). Press Yes to load (overwrites current).
3. View Current Schedule: Press MENU > Schedules > Heat and Cool. Current day displays; press Next for other days.
4. Set Heat/Cool Schedule: Press MENU > Schedules > Heat and Cool. For current day, use left/right arrows to select item (time, heat/cool setpoint), adjust with +/−. Press Next for other days.
5. Copy a Day Schedule: In Heat and Cool schedule, highlight small "c" with left arrow to show Copy button. Press Copy, set Y/N for target days using arrows and Yes/No buttons, then Copy.
6. Recovery: If enabled, starts system early to reach setpoint by schedule time (max 1 hour, displays "Recov"; no aux heat).

Settings Screen

Access via MENU > User Settings (or Installer Settings: hold two middle buttons).
SettingRange/DefaultDescription/Adjustment
Set ClockN/A / Current timeSet time, date, day (see Initial Setup).
Filter ServiceRuntime: 0+ hrs; Interval: 100-4000 hrs (default 300) or DisabledView/reset runtime (press Reset after filter change). Adjust interval with +/−; disable with − to Disabled. Counts fan runtime.
Maint ServiceHeat/Cool Runtime: 0+ hrs; Interval: 200-4000 hrs (default 3000) or DisabledView/reset heat/cool runtimes (press Reset after maintenance). Adjust interval with +/−; disable with − to Disabled. Triggers "Maint" message.
Screen Timeout0-120 sec (default 0)Time before minimized display (temperature only). Set 0 to disable. Adjust with +/−.
F/C SettingsF or C (default F)Select Fahrenheit or Celsius. Adjust with +/−.
Sensor Calibration±0-7°F (default 0)Calibrate internal sensor. Displays calibrated temp and offset; adjust with +/− (updates after ~seconds).
Backlite/DisplayTimeout: 0-120 sec (default 30); Contrast: 0-20 (default 10)Timeout: 0 = always on. Contrast: higher for lighter display, lower to avoid dark lines. Scroll and adjust with +/−.
Installer Settings:
SettingRange/DefaultDescription
Display LockY/N (default N)Y locks buttons (menu accessible but not selectable; unlock via Installer Settings).
Max Heat SP55-90°F / 90°FMaximum heating setpoint.
Min Cool SP60-99°F / 60°FMinimum cooling setpoint.
Min Run Time (MRT)1-9 min / 3 minMinimum on-time before cycle off (prevents rapid cycling; displays "Cool ON" or "Heat ON").
Min Off Time (MOT)5-9 min / 5 minMinimum off-time before next cycle (compressor protection; displays "WAIT").
T-Sense Match1-6 / 2Temperature sensor sample rate (1=less sensitive, 6=more sensitive).
Restore DefaultsN/AResets all settings to factory defaults.
System Settings (Under Installer):
SettingRange/DefaultDescription
Schedule EnableY/N / NEnables local scheduling.
Recovery EnableY/N / NEnables recovery to reach setpoint by schedule time.
H/C Delta3-15°F / 3°FMinimum heat/cool setpoint separation.
Heating Delta Stg1 ON/OFFON:1-8°F/1; OFF:0-8°F/0Delta from setpoint for stage 1 heat on/off.
Mechanical Settings:
SettingRange/DefaultDescription
TypeGas/Elec or Heatpump / Gas/ElecHVAC type.
Fan TypeGas or Elec / GasFan type for gas/electric systems.
C/O Typew/Cool or w/Heat / w/CoolHeat pump changeover.
2nd Stage HeatY/N / NEnables 2nd stage heat.
Aux Heat (HP)Y/N / YEnables auxiliary heat.
2nd Stage CoolY/N / NEnables 2nd stage cool.

Advanced Features

1. Usage Graph: Press MENU > Usage Graph. Shows daily heating/cooling runtime hours for the week (e.g., 5-20 hrs bars for Sun-Sat). Press Heat/Cool button to toggle views.
2. ESM Setpoints: Press MENU > ESM Setpoints. Set ESM-Heat and ESM-Cool with +/−. Used in Energy Saving Mode.
3. Z-Wave Install:

4. Thermostat Info: Press MENU > Thermostat Info. Displays model, firmware ver, Z-Wave ver, node ID, home ID, system type, fan type.
5. Thermostat Recovery Operation: Enabled via Recovery Enable (Y). In Run mode, learns to start system early for setpoint at schedule time (recalculates daily, max 1 hr, no aux heat).

Troubleshooting

Installation Instructions

Warning: Professional installation required. For complete installation instructions, browse to part2.schlage.com and download Trane Thermostat Installation Instructions.

Pre-Installation

Wiring Diagrams

Standard low-voltage for HVAC (professional wiring; see full manual for diagrams):

TerminalConnection
R24V Hot
CCommon
W1Heat Stage 1
Y1Cool Stage 1
GFan
O/BChangeover (HP)
W2Heat Stage 2
Y2Cool Stage 2

Note: For Z-Wave, connect via bridge; full diagrams in installation guide.

Configuration Options

  1. Power up; run User Setup for time/date/schedule.
  2. Enroll Z-Wave with bridge.
  3. Set thermostat options: Scale, RH setpoints, fan, schedule enable.
  4. Test modes; upgrade firmware via Schlage LiNK.

Calculation Tool

Estimate monthly energy savings from ESM (assumes 0.5 kWh/hr per °F difference; 30 days/month).