The Trane Schlage Link TSK400BBX is a remote energy management thermostat system compatible with single and multistage forced air systems, including gas/oil/electric furnaces, heat pumps, and air conditioning. It integrates with Schlage LiNK™ for Z-Wave remote control via broadband internet, enabling online scheduling, climate/lighting management, and energy monitoring. The starter kit includes the thermostat, cable, appliance module (for lamps/appliances), power supply, and bridge (requires 9V battery for enrollment). Below are the key specifications and operation instructions.
1. Power On: Display turns on after reconnection.
2. Set Time/Date: MENU > User Settings > Set Clock; adjust fields with arrows/Select.
3. Z-Wave Enrollment: Prepare bridge (unplug, insert 9V battery); hold near device; press + on bridge; press Z-Wave button (hold 2s) on thermostat/appliance module.
4. Schlage LiNK Account: Visit www.schlagelink.com; create account (credit card required); enroll devices via Climate/Lighting tabs.
5. Mechanical Settings: MENU > Installer Settings (hold inner buttons 3s) > System > Mechanical: Set type (Gas/Electric/HP), stages, fan, C/O.
1. Display: Time, setpoints (e.g., HEAT 60), mode (Sys Off/Heat/Cool), fan (AUTO), run status.
2. Controls: Up/Down for setpoints; MODE for Off/Heat/Cool/Auto/EM Heat; FAN for Auto/On; SCHEDULE for Hold/Run/ESM.
3. Menu: Access User Settings, Usage Graph, ESM, Z-Wave Install.
1. Enable: MENU > User Settings > Schedule > Enable (default Yes).
2. Edit: MENU > Schedule > Edit > Select day > Set periods (time/heat/cool, min 3°F delta) > Done.
3. Copy: Copy to other days post-edit.
4. Presets: ESM (default 62°F Heat/85°F Cool); manage via Schlage LiNK online (Schedules tab for scenes/events).
1. User Settings: MENU > Set Clock, Filter/Maint reminders (monthly-annually), Screen timeout (0-120s), Backlight (0-100%), Scale (F/C), Calibration (±7°F).
2. ESM: Adjust heat/cool setpoints.
3. Security: Display/Guest lock (hold up/down to disable).
4. Installer: Hold inner buttons + MENU: System type, stages, fan config, C/O type.
1. Z-Wave/Schlage LiNK: Remote climate/lighting control; appliance module as repeater (extend range).
2. Dehumidification: RH setpoints (Cool 30-60%, Heat 10-45%); overcooling.
3. Fan Cycler: Continuous options (Auto/On/Circ).
4. Recovery: Gradual temp recovery (Installer enable).
Warning: Professional installation; disconnect power. Not for metal structures (RF interference).
For Conventional (Gas/Electric Single/Multi):
| Existing | Trane/York | Other | Lennox | New |
|---|---|---|---|---|
| C/X/B | 24COM | C/COM/X/B | C | 24COM |
| R/RC/RH | 24RC/RH | R/RC/RH | R | 24RC/24RH |
| W/W1 | W1 | W1/W | W1 | W1 |
| W2 | W2 | W2 | W2 | W2 |
| Y/Y1 | Y1 | Y/Y1 | Y | Y1 |
| Y2 | Y2 | Y2 | Y2 | Y2 |
| G | G | G | G | G |
For Heat Pump:
| Existing | Trane/York | Other | Lennox | New |
|---|---|---|---|---|
| C/X/B | 24COM | C/COM/X/B | C | 24COM |
| R/RC/RH | 24RC/RH | R/RC/RH | R | 24RC/24RH |
| O/B/AUX | W2/O/B | O/B | O/B | W2/O/B |
| Y/Y1 | Y1 | Y/Y1 | Y | Y1 |
| Y2 | Y2 | Y2 | Y2 | Y2 |
| E/W1/AUX | W1 | E/W1/X/AUX | AUX | W1 |
| G | G | G | G | G |
Note: Cut JP1 if wires on both 24RC/24RH; secure wires, mount level, snap face.
Estimate monthly energy savings from ESM (assumes 0.5 kWh/hr per °F difference; 30 days/month).