The Trane Pivot Smart Thermostat is a programmable thermostat with a color touch-screen and intuitive user interface for easy operation. It supports remote access via iOS or Android mobile devices. Key elements include compatibility with heat/cool, dual fuel, heat only, cooling only, and heat pump systems. It uses proprietary PI control schemes for comfort and energy efficiency. Below are the key specifications and operation instructions.
1. Power On: Connect to HVAC system; sequence lasts 90–120 seconds; calibrate screen if prompted (5s window).
2. Set Basics: Follow prompts for language, time, date, temperature scale.
3. Register for Remote Access: Download Trane Pivot app (iOS/Android); create account; add thermostat using PIN/QR code.
4. Add Users: In app, tap Users > New User; enter details and scan QR/PIN.
5. Weather Setup: Set local weather via app after registration.
6. Enable Scheduling: Menu > Schedules > Enable.
1. Display: Indoor temperature, RH, setpoints, mode (heating/cooling/off), weather, network status, icons for occupancy/alerts.
2. Controls: Touch mode/fan/schedule; up/down arrows for setpoints.
3. Menu Access: Tap menu for Schedules, Setpoints, Occupancy Override, System Info.
4. Customization: Settings > Screen Layout: Select up to two apps for home screen (e.g., Schedules, Weather).
1. View/Edit: Menu > Schedules; enable if off; adjust periods per day (up to 4: Wake, Leave, Return, Sleep).
2. Add Periods: Tap Add > Set start time, heating/cooling setpoints > Save (max 4/day).
3. Delete Periods: Tap period > Delete > Save.
4. Setpoints: Menu > Schedule Setpoints > Adjust occupied/unoccupied heat (default 70°F)/cool (75°F); deadband (1-9°F, default 2°F).
5. Occupancy Override: Menu > Occupancy Override > Set duration and setpoints.
6. Temporary Adjustments: Arrows on home screen; tap occupancy icon in unoccupied mode.
1. Access: Menu > Settings.
2. Thermostat: Scale (°F/°C), deadband, calibrate sensors (±°F).
3. Screen: Brightness, backlight timeout, screen saver, themes; layout for home apps.
4. Weather: Local setup via app.
5. SW Upgrades: Manual check/install.
6. PIN Access: Set restrictions; enter for functions.
7. Emergency Heat: Enable for heat pumps; lockout range 5-70°F.
1. Mobile App: Manage thermostats/users/buildings; alerts (high/low temp); remote control/updates.
2. Alerts: Set triggers in app > Thermostat > Alerts (heating/cooling issues).
3. PIN Security: 4-digit code; set via app or thermostat.
4. Occupancy Override: Temporary mode change with duration.
5. System Info: Alerts, notifications, details.
6. Customization: Home layout; energy features like deadband/lockouts.
Warning: Qualified personnel only; hazards in HVAC equipment risk death/injury. Follow local codes; proper wiring/grounding required.
Standard low-voltage terminals (18 AWG max):
| Terminal | Connection |
|---|---|
| R | 24V Power |
| C | Common |
| G | Fan |
| Y1/Y2 | Cool Stages |
| W1/W2 | Heat Stages |
| O/B | Changeover (HP) |
| AUX1/AUX2 | Accessories (Humidifier/Dehum) |
| ODT | Outdoor Temp Sensor |
| RS1 | Binary Input (Occupancy) |
Note: Up to 2 stages; consult installer for system-specific diagrams.
Estimate monthly energy savings from scheduling (assumes 1% savings per °F setback; 30 days/month).