Trane Nexia TCONT624AS42DA Thermostat Operation Manual

The Trane Nexia TCONT624AS42DA is a Touchscreen Comfort Control for forced air heating and cooling HVAC systems, featuring a Z-Wave module for remote control via Nexia Home Intelligence. It provides typical operation for HVAC systems with remote access capabilities using a smartphone, tablet, or PC (requires SK101 bridge kit and Nexia account). The device includes an interactive 4.3” black & white touchscreen and supports 7-day programmable scheduling with 4 periods per day. Key elements include a built-in humidity sensor with RH display, maintenance reminders, remote temperature sensing options, and humidifier control.

1. Key Specifications 2. Operation Instructions 2.1. Initial Setup 2.2. Home Screen Navigation 2.3. Scheduling and Presets 2.4. Settings Screen 2.5. Advanced Features 2.6. Troubleshooting 3. Installation Instructions 3.1. Pre-Installation 3.2. Wiring Diagrams 3.3. Configuration Options 4. Calculation Tool

Key Specifications

Operation Instructions

Initial Setup

1. Set Time/Date: Menu > User Settings: Select Hour (1-12 am/pm), Minutes (0-59), Day of Week (Sun-Sat), Year (2013-2113), Month (Jan-Dec), Date (1-31). Defaults to factory preset 7-day energy savings schedule (e.g., Wake 6:00 AM: 70°F Heat/78°F Cool; Day 8:00 AM: 62°F Heat/85°F Cool; Evening 6:00 PM: 70°F Heat/78°F Cool; Night 10:00 PM: 62°F Heat/78°F Cool). Enable local scheduling (default Yes). Clock blinks if not set; auto-updates via Nexia if connected.
2. Z-Wave Enrollment: For Nexia integration, use SK101 bridge: Prepare bridge (unplug, install 9V battery, verify blue blink); hold within 6 ft; press + on bridge; Menu > Next to Z-Wave > Select; orange light solid when complete. Verify: Menu > Next to About > Next to Node ID (non-00 confirms).

Home Screen Navigation

1. Display: Clock (upper left), dynamic labels/function buttons, setpoint display with up/down arrows (adjust heat/cool; min 3°F separation), current temperature (internal sensor adjustable), Menu button (access settings), System Mode button (Off/Heating/Cooling/Auto/EM Heat), Fan Mode button (Auto/On/Circ with 1-59 min/hour), Schedule Mode button (Hold/Run/ESM).
2. Controls: Press setpoint button to adjust; MODE to change mode.
3. System Modes: Off, Heating, Cooling, Auto, EM Heat. Fan Modes: Auto, On, Circ.

Scheduling and Presets

1. Enable: Menu > User Settings > Schedule > Enable Schedule (ON).
2. Edit Schedule: Menu > User Settings > Schedule > Edit Schedule > Select Day > Set Time (up/down arrows) > Heat Setpoint > Cool Setpoint > Next through periods > Done to save.
3. Copy Schedule: After editing, select Yes to copy to next day(s) via Yes/No buttons > Done.
4. Schedule Modes: Hold (maintains current setpoints); Run (follows schedule); ESM (uses predefined setpoints).
5. 1-Touch Presets: Not explicitly detailed; use ESM for energy savings presets.

Settings Screen

1. Access: Menu > User Settings > Select > Next through options > Done to save.
2. Thermostat Settings: Temperature Scale (Fahrenheit/Celsius); Cooling RH Setpoint (30-60%, default 50%); Heating RH Setpoint (10-45%, default 40%); Smart Continuous Fan (Yes/No); Continuous Fan Airflow (35-100%); Fan Circulate On Time (1-59 min or Off); Local Schedule Enable (Yes/No); Max Heat Setpoint (55-90°F); Min Cooling Setpoint (60-99°F); H/C Delta (3-15°F).
3. Energy Savings Mode: ESM Heat Setpoint (55-90°F, default 62°F); ESM Cooling Setpoint (60-99°F, default 85°F).
4. Display: Screen Timeout (0-90 sec); Backlight Timeout (0-90 sec); Backlight On/Off Percent (0-100%); Buzzer Enable (Yes/No).
5. Security: Unlocked/Display Lock/Guest Access (default Unlocked); disable by holding up/down arrows.

Advanced Features

1. Reminders: Filtration (Yes/No, periods Monthly-Annually); System Maint (Yes/No, months).
2. Firmware Upgrades: Via mynexia.com > Edit Home > Firmware Updates > Update (up to 45 min).
3. About Screen: Menu > About: Version, ZWAVE Ver, Node-ID, Home-ID, Out-Type, C/O Type, In-Type.
4. Clean Screen: Menu > Clean Screen > Yes; use water/soft cloth.
5. Dehumidification/Humidification: Installer-enabled; RH setpoints adjustable.

Troubleshooting

Installation Instructions

Warning: Professional installation required. A 24 Volt common and hot wire MUST be connected for operation. Contact servicing dealer for full setup.

Pre-Installation

Wiring Diagrams

Standard low-voltage for HVAC (professional wiring; see installer manual):

TerminalConnection
R24V Power (Hot)
CCommon
W1Heat Stage 1
Y1Cool Stage 1
GFan
O/BChangeover (HP)

Note: For Z-Wave, connect via SK101 bridge; full diagrams in installer guide.

Configuration Options

  1. Power up; run User Setup Wizard for time/date/schedule.
  2. Enroll Z-Wave with SK101.
  3. Set thermostat options: Scale, RH setpoints, fan, schedule enable.
  4. Test modes; upgrade firmware via Nexia.

Calculation Tool

Estimate monthly energy savings from ESM (assumes 0.5 kWh/hr per °F difference; 30 days/month).







Trane Thermostat Manual© - All Rights Reserved 2025