The Trane Master Scheduler is a programmable thermostat designed for Trane Integrated Zone Systems, enabling centralized control of multiple zones in residential heating and cooling setups. It features setback scheduling for energy savings, temporary overrides, and compatibility with variable speed blowers. Supports 7-day programming with customizable periods and setpoints, maintaining a 4°F separation between heating and cooling. Below are the key specifications and operation instructions.
1. Install Batteries: Remove front cover; pull plastic strip from AA batteries.
2. Set Time: Press CLOCK; use arrows for time/day; press Run Program to exit.
3. Select Mode: Press HEAT/COOL for Heat/Cool/Auto/Off/Emergency Heat.
4. Fan: Press FAN for Auto/On (continuous, 50% speed when off in variable blowers).
1. Display: Shows time, zone temp, setpoint, mode, fan, period, outdoor temp (if sensor installed).
2. Zone Navigation: Press ZONE to cycle through zones; displays current zone status.
3. Outdoor Temp: Press OUTDOOR TEMP to view (-20°F to 120°F; -13°F if no sensor).
4. Backlight: Activates on key press.
1. Enter Schedule: Press SCHEDULE; select zone if multi-zone.
2. Set Periods: Use PERIOD for Wake/Away/Return/Sleep; arrows for time/setpoints (4°F separation auto-maintained).
3. Copy: Press COPY to duplicate periods/days; or copy full zone schedule.
4. Defaults: Mon-Fri: 6:30AM H70/C78, 10PM H65/C75; customizable.
1. System Setup: Hold EXIT + ZONE for 3s; set master zone (0 for scheduling only), calibration (CAL), schedule enable per zone.
2. DST: Press Daylight Time to toggle.
3. Filter Timer: Press FILTER; hold 3s to set/reset (0-360 days).
4. Exit: Press EXIT or timeout.
1. Temporary Override: Press arrows for temp change; holds until next period or manual cancel.
2. Permanent Hold: Press HOLD TEMP twice; set duration (up to 255 days for vacation).
3. Local Override: Changes at zone sensor show LOCAL; can override from master.
4. Lock: Hold EXIT + ZONE; LOCK icon appears until unlocked.
Warning: Professional installation required for zoned systems. Disconnect power before wiring.
For Integrated Zone System (professional wiring; terminals for power, zones, outdoor sensor):
| Terminal | Connection |
|---|---|
| R | 24V Power |
| C | Common |
| Z1-Zn | Zone Sensors |
| OS | Outdoor Sensor |
| F | Fan |
Note: Connect to zone dampers/communicating bus; see full installer manual for diagrams.
Estimate monthly energy savings from setback (assumes 1% savings per °F, 30 days/month).