The Trane Comfort Control XB200 (TCONT200AN11AA) is a basic digital thermostat for single-stage heat and cool conventional systems. It features an intuitive LCD display, manual mode selection, auto changeover, energy-saving offsets, and filter reminders for simple, efficient control. Below are the key specifications and operation instructions.
1. Power On: After installation, display shows room temperature.
2. User Setup: Press and hold MODE + FAN to enter; adjust temperature scale, changeover, deadband, etc., using arrows.
3. Defaults: Auto changeover enabled, 3°F deadband, 1°F cooling droop, 5°F energy offset.
1. Display: Shows current temperature, mode, fan status, time (if set), indicators (FILTER, SERVICE, WAITING).
2. Controls: MODE for system mode, UP/DOWN for setpoints, FAN for fan mode, FILTER/ENERGY SAVINGS for specials.
3. Backlight: Activates on key press for 10 seconds.
1. Heat/Cool: Press MODE to select; adjust setpoint with arrows.
2. Auto: Switches between heat/cool based on deadband.
3. Off: System inactive.
4. Fan: Auto (with system) or On (continuous).
1. Access: Hold MODE + FAN; navigate with MODE/FAN, adjust with arrows.
2. Options: Temperature scale, auto/manual changeover, deadband (2-10°F), waiting indicator, cooling droop (0-2°F), energy offsets (0-25°F), filter timer (1-180 days).
3. Exit: Timeout or advance to end.
1. Energy Savings: Press key to activate offset; hold for setup (separate heat/cool).
2. Filter Reminder: Press FILTER to view/reset timer; flashes when due.
3. Cooling Droop: Cycles compressor for humidity control.
4. Waiting Indicator: Shows "WAITING" during delays.
Warning: Professional installation required; disconnect power before wiring.
For 1H/1C Conventional:
| Terminal | Connection |
|---|---|
| R | 24V Power (Red) |
| W | Heat (White) |
| Y | Cool (Yellow) |
| G | Fan (Green) |
| C | Common (Blue) |
Note: No polarity; standard low-voltage setup.
Estimate monthly savings from energy offset (assumes 1% savings per °F offset, 30 days/month).