The Trane BAYSTAT152A is a touch-screen programmable thermostat designed for conventional rooftop units, air conditioners, and heat pumps. It provides automatic HVAC control with an LCD touch screen displaying temperature, setpoints, modes, time, and occupancy. Supports programmable/non-programmable modes, scheduling, temporary overrides, and remote sensors for temperature/humidity. Below are the key specifications and operation instructions.
1. Power On: Apply HVAC power; thermostat runs power-up test (checks voltage/sensors; displays errors if any).
2. Set Time/Date: Touch clock icon; adjust hour/minute/day/month/year with arrows; save.
3. System Mode: Touch mode icon; select Heat/Cool/Auto/Off/Em Heat.
4. Dehumidify: If enabled, touch humidity icon to set 40-60% RH.
1. Display: Current temp (local/remote/outdoor), setpoints, time/day, mode, fan, occupancy, humidity, alerts (e.g., filter).
2. Controls: Touch icons for mode/fan/schedule; arrows for setpoints.
3. Icons: System mode, fan, time, occupancy, temp arrows, humidity, outdoor temp.
1. Access: Touch schedule icon; select day/group (All/Mo-Fr/Sa-Su).
2. Periods: 2 or 4 per day; set start times (e.g., 6AM/8AM/6PM/10PM), setpoints (heat 70°F/62°F, cool 78°F/85°F), fan/occupancy.
3. Defaults: ENERGY STAR compliant (e.g., mornings/evenings 70°F heat/78°F cool).
4. Save: Changes auto-save; cancel discards.
1. Access: Installer menu (hold center 5s); set units (Option 0100), changeover (0110), CPH (0162-0172).
2. Filter Reset: Hold arrows 3s.
3. Lockout: Option 0290 (code required).
4. Offset: ±3°F display (0220).
1. TOV: Touch fan for quick (up to 4 hrs); or user custom time/setpoint/fan.
2. Remote Sensors: Temp (0210: local/remote/outdoor), humidity (0200).
3. Non-Programmable: Option 0140=1 for manual only.
4. Economizer/TOD: Option 0150; fan extension (90s cool/40s heat).
Warning: Qualified personnel only; disconnect power, lockout/tagout to avoid hazards.
For various systems (11 options):
| Terminal | Connection |
|---|---|
| R/Rc/Rh | 24V Power |
| W1/W2 | Heat Stages |
| Y1/Y2 | Compressor Stages |
| O/B | Changeover Valve |
| G | Fan |
| C | Common |
| S1/S2 | Remote Temp Sensor |
| Hp/Hs | Remote Humidity Sensor |
Note: Jumper Rc/Rh for single transformer; see manual Figures 4-14 for full diagrams.
Estimate monthly savings from scheduling setback (assumes 1% savings per °F, based on CPH duty cycle; 30 days/month).