Trane BAYSTAT150A Thermostat Operation Manual

The Trane BAYSTAT150A is a programmable digital thermostat designed for 3-stage heat/2-stage cool systems, including heat pumps and conventional setups. It features a touch-screen interface, ENERGY STAR compliant scheduling, timed overrides, and compatibility with remote sensors for efficient HVAC control. Below are the key specifications and operation instructions.

1. Key Specifications 2. Operation Instructions 2.1. Initial Setup 2.2. Home Screen Navigation 2.3. Scheduling and Presets 2.4. Settings Screen 2.5. Advanced Features 2.6. Troubleshooting 3. Installation Instructions 3.1. Pre-Installation 3.2. Wiring Diagrams 3.3. Configuration Options 4. Calculation Tool

Key Specifications

Operation Instructions

Initial Setup

1. Time Setup: From Home screen, press sequence of buttons to enter; adjust hours/minutes with arrows; save and exit.
2. System Mode: Press buttons to access; select mode (Emergency Heat, Cool, Auto, Off, Heat); save.
3. Fan Mode: Press to toggle On/Auto; overrides enter TOV in programmable mode.

Home Screen Navigation

1. Display: Shows current time, mode, fan setting; press buttons for setups.
2. Access: Use arrow buttons for adjustments; hourglass indicates TOV.
3. Overrides: Press arrows twice to enter TOV mode.

Scheduling and Presets

1. Create/Edit Schedule: Press button sequence to enter; select days, periods (up to 4), start times, heat/cool setpoints, fan.
2. Configurations: 1-day, 5+1+1, 5+2, or 7-day.
3. Defaults: ENERGY STAR compliant (e.g., Mon-Fri: Morning 70°F heat/78°F cool, Night 62°F heat/85°F cool).

Settings Screen

1. Access: Via button sequences for time, mode, fan, schedule.
2. Adjustments: Scroll and select days/periods/setpoints/fan; save by holding button or waiting.
3. Occupancy: Set during TOV or schedule.

Advanced Features

1. Timed Override (TOV): Temporary changes to setpoints/fan/occupancy; enter with arrows; set duration up to 99 days/23 hours; hourglass icon.
2. Fan Override: Temporary in programmable mode.
3. Exits: Timer end, manual save, or mode change.

Troubleshooting

Installation Instructions

Warning: Qualified personnel only; observe all safety precautions to avoid hazards.

Pre-Installation

Wiring Diagrams

For 3H/2C Heat Pump/Conventional:

TerminalConnection
R/Rc/Rh24V Power
Y1/Y2Compressor Stages
W1/W2/AuxHeat Stages/Aux
O/BReversing Valve
E/W2Emergency Heat
GFan
CCommon
S1/S2Remote Sensor

Note: Jumper Rc/Rh if single transformer; refer to full manual for diagrams.

Configuration Options

  1. Enter config mode post-install (hold buttons).
  2. Set system type, scheduling (0233: 1/5+1+1/5+2/7-day).
  3. Enable programmable (0140=1), fan.
  4. Test modes and save.