The Trane BAYSTAT150A is a programmable digital thermostat designed for 3-stage heat/2-stage cool systems, including heat pumps and conventional setups. It features a touch-screen interface, ENERGY STAR compliant scheduling, timed overrides, and compatibility with remote sensors for efficient HVAC control. Below are the key specifications and operation instructions.
1. Time Setup: From Home screen, press sequence of buttons to enter; adjust hours/minutes with arrows; save and exit.
2. System Mode: Press buttons to access; select mode (Emergency Heat, Cool, Auto, Off, Heat); save.
3. Fan Mode: Press to toggle On/Auto; overrides enter TOV in programmable mode.
1. Display: Shows current time, mode, fan setting; press buttons for setups.
2. Access: Use arrow buttons for adjustments; hourglass indicates TOV.
3. Overrides: Press arrows twice to enter TOV mode.
1. Create/Edit Schedule: Press button sequence to enter; select days, periods (up to 4), start times, heat/cool setpoints, fan.
2. Configurations: 1-day, 5+1+1, 5+2, or 7-day.
3. Defaults: ENERGY STAR compliant (e.g., Mon-Fri: Morning 70°F heat/78°F cool, Night 62°F heat/85°F cool).
1. Access: Via button sequences for time, mode, fan, schedule.
2. Adjustments: Scroll and select days/periods/setpoints/fan; save by holding button or waiting.
3. Occupancy: Set during TOV or schedule.
1. Timed Override (TOV): Temporary changes to setpoints/fan/occupancy; enter with arrows; set duration up to 99 days/23 hours; hourglass icon.
2. Fan Override: Temporary in programmable mode.
3. Exits: Timer end, manual save, or mode change.
Warning: Qualified personnel only; observe all safety precautions to avoid hazards.
For 3H/2C Heat Pump/Conventional:
| Terminal | Connection |
|---|---|
| R/Rc/Rh | 24V Power |
| Y1/Y2 | Compressor Stages |
| W1/W2/Aux | Heat Stages/Aux |
| O/B | Reversing Valve |
| E/W2 | Emergency Heat |
| G | Fan |
| C | Common |
| S1/S2 | Remote Sensor |
Note: Jumper Rc/Rh if single transformer; refer to full manual for diagrams.
Estimate monthly energy savings from ENERGY STAR setback (assumes 1% savings per °F setback, 30 days/month).