The Trane 3H/2C Thermostat is a programmable wall-mounted control designed for multi-stage heat pump systems with up to 3 stages of heat (including auxiliary/emergency) and 2 stages of cooling. It features an LCD display, scheduling capabilities, remote sensor support, and configuration options for efficient HVAC control. Available in programmable (BAYSTAT150A) and non-programmable (BAYSTAT155A) versions. Below are the key specifications and operation instructions.
1. Power On: Displays firmware version, then home screen or error code.
2. Configure: Hold config button 3 sec to enter mode; set system type (11 for programmable 3H/2C).
3. Time Set (Programmable): Hold ↑+↓+Mode+Fan+Prog 3 sec; adjust hour/minute.
1. Display: Current temperature, mode (Heat/Cool/Auto/Off/Emergency), fan (Auto/On), time/period (programmable).
2. Toggle Views: Hold ↑+↓ 3 sec to cycle: temp, setpoint, outdoor (if sensor).
3. Adjust: Press ↑/↓ for setpoints; Mode/Fan buttons to change.
(Programmable Only)
1. Enable: Press Prog; select days/periods.
2. Periods: 2 or 4 per day (e.g., morning 70°F heat/78°F cool; defaults vary by option).
3. TOV Override: Adjust ↑/↓, then set duration (up to 4 hrs), fan, occupancy.
4. Non-Programmable: Manual setpoints only; no scheduling.
1. Access: Hold config 3 sec; scroll options with arrows.
2. Key Settings: Temp resolution, clock format, deadband (2-9°F), CPH rates, lockouts.
3. Lock: In mode, hold ↑+↓ 4 sec (icon shows).
4. Exit: Press config or wait 10 min.
1. Remote Sensor: Config to display/use outdoor temp for lockouts (e.g., compressor below 45°F).
2. Aux Heat: Comfort/economy mode (non-programmable).
3. Economizer: A terminal for TOD/cool calls.
4. Extended Fan: 90 sec post-heat, 40 sec post-cool.
5. Emergency Heat: Manual activation; L terminal indicator.
Warning: Qualified personnel only. Disconnect power before wiring. Max wire resistance 2.5 ohms.
For 3H/2C Heat Pump with Aux (jumper Rc/R if single transformer):
| Terminal | Connection |
|---|---|
| Rc/R | 24V Power |
| Y/Y2 | Compressor Stages 1/2 |
| O/B | Changeover Valve (O in Cool) |
| W/Aux | Aux Heat |
| W2/E | Emergency/Aux Heat |
| G | Fan |
| C | Common |
| L | Emergency Indicator |
| A | Economizer/TOD |
| S1/S2 | Remote Sensor |
Note: Programmable has two terminal blocks; see manual figures for dual transformer.
Estimate stage 1 runtime percentage based on temperature difference (ΔT) and cycles per hour (CPH). Assumes duty cycle = ΔT / 20 (capped at 100%); runtime % = duty cycle * 100.