The Trane 1H/1C Thermostat is a non-programmable wall-mounted control designed for single-stage heat and single-stage cool conventional HVAC systems. It provides simple, reliable temperature control with an LCD display for current temperature, setpoints, and system modes. Ideal for residential applications, it supports automatic changeover and fan control. Below are the key specifications and operation instructions.
1. Power On: After installation, the thermostat powers up and displays current room temperature.
2. Configure Basics: Use UP/DOWN buttons to set initial heat/cool setpoints.
3. System Check: Enter configuration mode to verify system type (Option 01 for 1H/1C Conventional).
1. Press the MODE button to cycle through: OFF, HEAT, COOL, AUTO.
2. AUTO mode switches between heat and cool based on setpoints and deadband.
3. Display shows selected mode and setpoint.
1. Press the FAN button to toggle: AUTO (runs with system), ON (continuous).
2. Useful for air circulation without heating/cooling.
1. In HEAT mode, use UP/DOWN to set heating setpoint.
2. In COOL mode, adjust cooling setpoint similarly.
3. Changes take effect immediately; system maintains until manually adjusted.
1. Indicators: Space occupied/unoccupied, timed override, button lock.
2. Overrides: Temporary setpoint changes; no permanent hold needed.
3. Lock: Hold UP and DOWN for 5 seconds to lock/unlock buttons.
Warning: Only qualified personnel should install. Disconnect power before wiring. Improper installation can cause injury or equipment damage.
For 1H/1C Conventional (System Type Option 01):
| Terminal | Connection |
|---|---|
| R | 24V Power (Red) |
| W | Heat (White) |
| Y | Cool (Yellow) |
| G | Fan (Green) |
| C | Common (Blue, optional for battery backup) |
Diagrams: Connect to furnace/AC terminals: R to R, W to W, Y to Y, G to G. No polarity.
Estimate cooling runtime based on temperature difference (ΔT) and cycling rate. Assumes standard 30-min cycle (2 cycles/hour); runtime = (ΔT / 20) * cycle time.